Supervisor level
87
Peak load signal
External hardware is connected via the
Miele XCI box.
The peak-load negotiation function
enables the tumble dryer to be con-
nected to an energy management sys-
tem. When a signal is registered, the
tumble dryer's heater is switched off
for a short period or the appliance is
prevented from being switched on.
The tumble dryer may only be oper-
ated with a peak-load system if this
system is connected to the tumble
dryer via the Miele XCI box.
– Factory default: no function
– Peak load with 230 V
– Peak load with 0 V
Peak load prevention
With this function, the application of a
hygiene programme is not amended
when a peak load signal is in place.
The heater stays switched on.
– Factory default: Off
– On
COM module selection
This tumble dryer is equipped with an
integrated WiFi module. However, the
dryer can also be equipped with an
external module.
– Off
– Internal module (factory default)
The internal WiFi module is used.
– External module
An XKM module or RS232 module is
inserted into the module slot.