The ironed laundry can be very hot when
it comes out of the ironer. Wear gloves to
protect your hands.
In pauses between ironing, withdraw the
heater plate and reduce the temperature.
Baffle – exhaust ducting
A baffle is built into the exhaust ducting
which can be used to adjust the amount of
air flowing through the roller covering.
To open the baffle fully:
Turn the hexagonal screw (SW 19) in an
anti-clockwise direction as far as it will go.
To close the baffle:
Turn the hexagonal screw (SW 19) in
clockwise direction as far as it will go.
The ideal setting is reached when the roller
dries out sufficiently to leave no water spots
either on the covering or on flatwork with the
lowest throughput of air.
If the air throughput is too high, the roller will
cool down too much, thus reducing the
ironer’s performance.
Pick-off bands
The pick-off bands are used for picking
laundry off the roller. Laundry does not need
to be removed manually from the roller. If
one of the pick-off bands is dislocated by a
piece of laundry, it should be pushed back
into position manually.
After ironing
^
After ironing let the roller run for approx. 5
minutes on the lowest temperature setting
to let the roller covering dry out.
Warning:
The finger guard will be very hot if the ironer
is switched off after being run at the
maximum temperature setting.
^
Press
s
to switch the machine on.
^
Switch off the electricity supply to the
machine.
^
On rotary ironers without an integrated
compressor: Turn off the on-site
compressed air stopcock.
,
Allow the ironed laundry to cool down
before packing or storing it. Hot laundry
could self-ignite and cause a fire.
Ironing
M.-Nr. 05 567 240 /03