Switch on the electricity supply to the
machine.
^
On rotary ironers without an integrated
compressor: open the on-site compressed
air stopcock.
^
Press
s
to switch the machine on.
^
Turn the temperature selector
p
anti-clockwise to the lowest setting.
^
Presss the Start
h
button.
The
!
Heating indicator light comes on
and the heater plate heats up. The
°C
display shows the current temperature of
the heater plate.
^
When the
!
heating indicator light has
gone out, press the Start
h
button again.
The heater plate moves up to the roller and
the roller starts turning.
^
Use the temperature selector
p
to select
the temperature according to the type of
fabric.
Material
Temperature °C
Perlon/artificial silk
approx 100
Silk/wool
approx 150
Cottons/linen
approx 180 -200
^
Use the speed selector to select the m/min
speed of the roller.
,
Check that the finger guard is
functioning properly.
^
Start ironing by feeding laundry in from the
feed-in table, making sure it lies flat across
the feed-in belts as it goes in.
^
Smooth items from the middle outwards
towards the edges.
^
Do not restrict ironing of smaller articles to
any one part of the roller. Make use of the
whole roller width.
Ironing