Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
114
Electrical connection
The refrigeration appliance must only be
connected using the connection cable
supplied (AC 220–240 V 50 Hz supply).
Appliance plug connector
Mains plug
A longer connection cable is available
to order from Miele .
The fuse rating must be at least 10 A.
This appliance must be connected to a
suitable switched socket. The electrical
installation must be comply with current
local and national safety regulations
(e.g. VDE 0100 in Germany).
The socket must not be concealed be-
hind the refrigeration appliance and
must be easily accessible so that the
appliance can be quickly disconnected
from the electrical supply in case of an
emergency.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole con-
tact gap of at least 3 mm. These in-
clude circuit breakers, fuses and con-
tactors (EN 60335).
The mains plug and mains connection
cable must not come into contact with
the back of the refrigeration appliance
as vibrations can cause damage to
these components. This could result in
a short circuit.
Do not plug in other appliances behind
this refrigeration appliance.
Do not connect the appliance to the
mains electricity supply using an exten-
sion lead. Extension leads do not guar-
antee the required safety of the appli-
ance (e.g. danger of overheating).