Water inlet
,
Water in the machine is not
suitable for drinking.
^
The machine must be connected to
the water supply in accordance with
local and national regulations.
^
The washer is constructed so it may
be connected to a supply without an
extra non-return valve, unless
required by code.
^
Acceptable water pressure (flowrate)
is 10 - 145 psi. However the
recommended pressure is 25 - 60 psi
If the water pressure is below 30 psi,
the fill time will take longer.
If the water pressure is not in the
range of 10 - 145 psi the message
CHECK WATER INLET will be
displayed. Contact the Miele
Technical Service Department.
^
The machine is supplied standard to
be connected to a cold (coded blue)
and
a hot (coded red) water supply
to a maximum temperature of 158 °F
(70 °C).
Connect the water intake hoses to the
cold and hot water faucets. The
steam condenser inlet hose (without
waterproof connector) should be
connected to the cold water supply,
using the adapter supplied
If no hot water supply is available,
the hot water inlet hose marked
red
should also be connected to a cold
water supply by a y-adapter.
For a DI-water connection (H2O
pure), see next page.
^
Water valves with
3
/
4
" (2 cm) male
hose thread are to be provided on
site. They should be easily
accessible so the water supply can
be turned off if necessary.
^
The inlet hoses are 5
1
/
2
feet (1.7 m)
long, terminating in a
3
/
4
" ( 2 cm)
female hose thread.
The water inlet
filters in the threads must not be
removed.
^
Large surface area filters are
enclosed in the kit supplied with the
machine.
Install these filters between the water
valve and the water inlet hose (see
illustration in "Cleaning the water inlet
filters"). The large surface area filter
for DI water is made from stainless
steel and can be recognized by its
matte surface.
,
Do not cut the inlet hose or
damaged in any way.
^
See also the installation diagram
supplied.
Plumbing