background image

11715550-03

Installation

*INSTALLATION*

Electrical connection

The dishwasher is “connector-ready” as
standard for connection to an earthed
socket.

The socket must be easily accessible
after the dishwasher has been installed.
If that is not possible, ensure that a
suitable means of disconnection is
provided on the installation side for
each pole.

Risk of fire from overheating.

Connecting the dishwasher to a
multi-socket adapter or to an
extension lead can overload the
mains connection cable.
For safety reasons, do not use an
extension lead or multi-socket
adapter.

The electrical installation must comply
with VDE 0100 requirements.

For safety reasons, we recommend
using a type 

 residual current device

(RCD) in the assigned electrical
installation for connecting the
dishwasher.

If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of
the same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified
specialist or the Miele Customer
Service Department.

These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical
connection.
If in any doubt, consult a qualified
electrician.

Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN˽50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of BS OHSAS 18001–2
ISO 45001.

Summary of Contents for G 5050 C SCVi Active

Page 1: ...e connected to cold or hot water up to max 60 C supplies If energy saving water heating sources such as solar energy circulation systems are used we recommend connecting to the hot water supply This saves both time and electrical energy costs Hot water is used in all programmes The water inlet hose is approx 1 5 m long A 1 5 m long flexible metal extension hose tested to 14 000 kPa 140 bar is avai...

Page 2: ...lied with the dishwasher must be installed between the tap and the water intake hose Screw the non return valve onto the stopcock Screw the water inlet hose onto the thread of the non return valve Risk of damage due to excessive pressure A brief increase in the water pressure can damage components of the dishwasher This dishwasher must only be operated when it is connected to a fully vented plumbi...

Page 3: ...ead no higher than 1 m If the hose is to be directly fitted to the drainage outlet on site use the hose clip supplied see installation plan The hose can be directed to the left or the right of the appliance The on site connector for the drain hose can be adapted to different hose diameters If the connector extends too far into the drain hose it must be shortened Otherwise the drain hose can become...

Page 4: ...tem must be vented Otherwise a siphoning effect during a programme can cause the appliance to empty itself of water Open the dishwasher door fully Remove the lower basket Insert a screwdriver into the middle opening of the vent valve in the left wash cabinet wall Press the screwdriver further into the opening and push it through the membrane behind The vent opening for the water drain is now open ...

Page 5: ...omer Service Department For safety reasons such replacement may only be carried out by a qualified specialist or the Miele Customer Service Department These operating instructions and the data plate indicate the nominal power consumption and the appropriate fuse rating Compare this information with the data of the on site electrical connection If in any doubt consult a qualified electrician Tempor...

Reviews: