16
Switch on the blower
Power levels
1
to
3
are available for light
to heavy cooking vapors and odors.
If heavy cooking vapors and odors
occur temporarily, e.g., during frying,
select stage
B
as booster level.
Use the blower switch
to turn on
the blower and select the appropriate
power level.
Cooking on a high setting causes
very high temperatures in the
ventilation hood.
Excessive temperatures may
damage the ventilation hood.
Always switch on the ventilation hood
when using the cooktop.
Particularly when using gas cooktops,
one of the following blower levels
should be selected depending on
which cooking level is selected.
Ventilation hood with blower DRIB/
DREB XL (700 cfm)
Gas power level
switched on
Minimum
blower level
from approx.
75,000 BTU/h (22 kW)
2
from approx.
105,800 BTU/h
(31 kW)
3
Ventilation hood with blower DRIB/
DREB XXL (1100 cfm)
Gas power level
switched on
Minimum
blower level
from approx.
105,800 BTU/h
(31 kW)
2
from approx.
136500 BTU/h
(40 kW)
3
The ventilation hood is fitted with a
temperature sensor. If a blower level
that is too low is selected, the
ventilation hood automatically
switches temporarily to the booster
level. This occurs even if the
ventilation hood is switched off.
Summary of Contents for DAR 1**0
Page 12: ...Guide to the appliance 12 ...
Page 26: ...Installation 26 Installation parts ...
Page 28: ...Installation 28 Appliance dimensions Blower modules DAR 1120 DAR 1130 DAR 1150 ...
Page 29: ...Installation 29 DAR 1220 DAR 1230 DAR 1250 DAR 1260 Range Wall Hood ...
Page 39: ...M Nr 10 463 980 00 en US DAR 1120 DAR 1130 DAR 1150 DAR 1220 DAR 1230 DAR 1250 DA 1260 ...