Operation (Automatic and Manual modes)
33
Filter saturation indicator
The ventilation hood registers the length
of time it has been operated.
The filter saturation indicators show
when the filters need to be cleaned or
changed by lighting up the grease filter
symbol
or charcoal filter symbol
.
Additional information on cleaning and
changing the filters and resetting the
filter saturation indicators can be found
under “Cleaning and care”.
Adjusting the filter saturation
indicator for the grease filters
You can set the filter saturation
indicator to suit your cooking habits.
The factory default setting is a cleaning
interval of 30 hours.
– Select a shorter interval of 20 hours if
you fry food regularly.
– We also recommend a shorter
cleaning interval if you only cook
occasionally. This will prevent grease
build-up from hardening and making
cleaning more difficult.
– Select a longer cleaning interval of 40
or 50 hours if you use very little fat
when cooking.
Switch off the blower and the lighting.
Touch the delayed shutdown
control
and the grease filter
control
at the same time.
The grease filter symbol
and one of
the blower power level indicators will
flash.
The indicators
1
to
B
show the current
time setting:
1
............................................... 20 hours
2
............................................... 30 hours
3
............................................... 40 hours
B
.............................................. 50 hours
Touch the relevant control to select
the duration required.
Confirm your choice by touching the
grease filter control
.
All the indicator lights will go out.
If the new setting is not confirmed
within 4 minutes, the ventilation hood
will revert to the previous setting.