Cleaning and care
39
Replace the grease filter, making sure
that the locking clip is facing
outward.
If the filter has been installed
incorrectly, you can insert a small
screwdriver into the slit to disengage
the locking clip.
Close the canopy and press it on the
right and left into the catch.
Resetting the filter saturation
indicator for the grease filters
Once cleaning is complete, the filter
saturation indicator must be reset.
While the blower is turned on, touch
the grease filter control
for approx.
3 seconds, until only the
1
is flashing.
The grease filter symbol
goes out.
When cleaning the grease filters before
the full operating time has elapsed:
Touch the grease filter control
for
approx. 6 seconds, until only the
1
is
flashing.
OdorFree Charcoal Filter
With recirculation mode, a charcoal
filter must be fitted in addition to the
grease filter. The charcoal filter is
designed to absorb cooking odors.
The charcoal filter is fitted in the top of
the ventilation hood.
How to install/replace a charcoal
filter
Take the charcoal filter out of its
packaging.
Fit the charcoal filter into the holder in
the top of the ventilation hood.