To switch the fan on
^
Press the On/Off touch control.
The fan runs at power level "II".
The indicator lamp will come on.
If the cooker hood has been
connected to a window contact
switch via the DSM 400 control
module, then the fan cannot be
switched on if the window is shut.
The indicator lamp will flash.
To select a power level
^
Use the
–
/
+
controls to select the
power level required.
+
control = higher setting
–
control = lower setting
Depending on the intensity of the
cooking vapours, levels I to III are
usually sufficient for normal cooking.
Intensive setting
For short periods of cooking food with
intensive vapours and a strong aroma,
e.g. when searing meat, you may wish
to select the Intensive Setting "IV".
Automatic switch-off of the Intensive
setting
You can set the Intensive setting so that
it only runs for 10 minutes before
reverting automatically to level III.
^
To set this option, both the fan and
the hob lighting must be switched off.
^
Press the run-on option touch control
for approximately 10 seconds. The
first fan setting indicator will light up.
^
Then press in turn,
– the touch control for the lighting,
– the
–
touch control, and
– finally the touch control for the
lighting again.
Operation
15
Summary of Contents for DA 428-4
Page 12: ...Guide to the appliance 12 ...
Page 28: ...Assembly parts Installation 28 ...
Page 39: ...39 ...