Cleaning the container and agitator
Clean the container and agitator
every six months.
^
Remove the lid.
^
Pour any remaining powder
detergent into another container to
keep it for future use.
^
Remove the dosing cog as described
on the previous page.
^
Before unscrewing the coupling,
make sure that the agitator is visible
in the detergent compartment.
Otherwise it will not be possible to
remove the agitator later on.
^
If necessary, use the coupling to turn
the agitator a bit further.
^
Use a screwdriver to unscrew the
screw from the coupling and then
remove the coupling from the
agitator.
^
Turn the container over.
^
Remove the agitator.
Cleaning and care