background image

 9 

Here is an abbreviated “Cheat Sheet” from NCI  

PRIME 

1.  BLANK  

 

DISTANCE

 

2.  FT. Covered    After 5280 FT. Switch to MILE

 

 

 

IMPLEMENT WIDTH

 

3.  Boom Switch Box OFF 

– 0 

     Boom Switch ON 

– Swath in FEET

 

Must set Flow Control        (LIQ) AUTO RANGE 

– HOLD

 

See Note (2)                       (DRY) HYD. VALVE 

– CLOSED

 

TOTAL APPLIED

 

 4.  0  to Start            Total LBS/AC Applied

—Spread

 

APPLICATION RATE

 

5.  Desired 

LBS/AC 

will oscillate

 

% RATE

 

6.  100 ALWAYS, if other than 100 change Target Rate 

– LBS/AC

 

 

 

PRODUCT VOLUME

 

7.  Enter full capacity from Constant in Set Up (GC).  Weight to match ma-   

terial in unit. Then number shows how much material remains in unit. 
Beeps at 10% of entered weight.  See Note (3)

 

TOTAL AREA

 

8.  0 to start   May require special instruction

 

      

DO NOT ZERO OUT UNTIL END OF DAY or INTERVAL OF CHOICE

 

FIELD AREA

 

9.  0 to start            Change Finish Job

 

SPEED

 

10.  MPH travel      0 is still

 

SCAN

 

11.  Totals and setting of some selector functions

 

TEST SPEED

 

12.  10 MPH 

– Blinks during testing only

 

PRIME

 

A.  

– Stnd

 

DISTANCE

 

B.  

Calibration Number 

See Note (1)  This must be checked

 

 

 

IMPLEMENT WIDTH

 

C. 

Swath

 

in inches    50’ = 600‖; 60’ = 720‖ 

      Lock in position with conveyor interface master on (Number 1 lit 

with single switch is dry swath) 

      *Must fill out all Slots 2

—9 with a value ―0‖ 

 

TOTAL APPLIED

 

D. 

Spreader Constant 

must match gate height for unit 

       GET OUT of the truck and check!  

APPLICATION RATE

 

E.  Must match 

density

 in LBS/CU FT

 

% RATE

 

F.  10%    Change rate by increments of +  or  -  10%  

 

PRODUCT VOLUME

 

G. 

LBS   Enter as constant  12’ Body = 14000 lb  /   10’ Body = 12000 lb 

TOTAL AREA

 

H.  ERR

 

FIELD AREA

 

I.  ―0‖  - Enter acre to hear audible alarm

 

SPEED

 

J.  Set GSO to ―0‖ on dry—ALWAYS

 

SCAN

 

K.  ERR

 

TEST SPEED

 

L.  10 MPH Steady  suggested for testing 

 

OPERATE 

SET UP 

Under Set Up most displays blink. 

NOTES 
(1)  Radar constant will vary with radar type: Mid-Tech Compact Radar - Start at 780  or  DickeyJohn Radar - Start at 1000   
(2)  Check Valve Setting

—Dry—Closed 

(3)  Enter by constant in setup.  (G) To go to a higher number, must go down then back up. 

Highlighted Items 

MUST be performed at the beginning of each job.  All other fields 

are for information and should be reset at your discretion

©2011 Newton Crouch Inc.  This information is the property of Newton Crouch Inc. and is loaned confidentially to our customer for his sole use.  It must not be used in any way 

detrimental to our interest or shared with outside parties. Technical Tips/ ARC6000 Programming—Dry                          Rev 2.2.2011 

Summary of Contents for TeeJet Mid-Tech ARC 6000

Page 1: ...onsole prior to jump starting welding or charging battery The TeeJet ARC 6000 User Guide is available online in pdf format at www teejet com Products Application Control and Equipment 2011 Newton Crou...

Page 2: ...oom Switch ON OFF Indicators Displays Data 1 Liquid Pressure normal pressure based spraying 2 Liquid Standard normal flow based spraying 3 Liquid Reflow used on some European sprayers 4 Granular Stand...

Page 3: ...constant from the chart Have to know chain type width plus encoder type It must match the gate height Application Rate __________ Step 5 This is your product in lbs cu ft If the product density is not...

Page 4: ...2 This is a personal choice 7 10 mph are common This number is for testing only With these selections you are now ready to enter the data into your console H I J K L Move switch down Change Console to...

Page 5: ...een will scroll through selections 4 C Stnrd 5 C SPL it 1 L PSI 2 L Stnrd 3 L rEFLO Liquid Dry Be sure you are in the correct mode These selections look very similar Look for the C 2011 Newton Crouch...

Page 6: ...crease accordingly The number one should light red This is your dry swath Numbers 2 9 should have a ZERO value 1 your swath is entered in INCHES 50 ft swath 600 in 60 ft swath 720 in 80 ft swath 960 i...

Page 7: ...t number for your load This is the amount of deviation from your desired application rate that you allow It changes in increments of 10 Usually it is not desirable to have your spread rate deviate sub...

Page 8: ...r that threshold is passed It is usually 1 acre Twist Display Selector to Total Area Display will show Err This number is a cumulative total of all jobs you have spread since you last cleared the cons...

Page 9: ...onveyor interface master on Number 1 lit with single switch is dry swath Must fill out all Slots 2 9 with a value 0 TOTAL APPLIED D Spreader Constant must match gate height for unit GET OUT of the tru...