 2 

BE SURE THE CONSOLE IS SELECTED TO THE                                               

CORRECT APPLICATION PROGRAM  

There are 5 choices total   

Liquid 

                  or                        

Dry  

  

 

Programming for your Mid-Tech ARC 6000 Console Granular 

Console calibration is a one-time procedure that, once it has been performed, does not 
have to be repeated.  Turning the POWER ON/OFF switch does not affect the console’s 
memory

—all data is retained

.

 

Turns the console 

power ON or OFF 

Mode Selector Switch                                        

selects either Operate 

or SetUp mode 

INC/DEC Switch 

changes values in 

display 

Display Selector Function Knob is 
used for Operate or SetUp in both 

Granular and Liquid 

Boom Switch ON / OFF 

Indicators 

Displays 

Data 

1.  Liquid Pressure

—normal pressure based spraying 

2.  Liquid Standard

—normal flow based spraying 

3.  Liquid Reflow

—used on some European sprayers 

4.  Granular Standard

—single conveyor spreader 

5.  Granular Split Drive

—dual conveyor spreader 

The control console must be calibrated & programmed before it is ready to be used

.    

4.  C  Stnrd 

5.  C  SPL 

1. 

L  PSI 

2. 

L  Stnrd 

3. 

L  rEFLO 

©2011 Newton Crouch Inc.  This information is the property of Newton Crouch Inc. and is loaned confidentially to our customer for his sole use.  It must not be used in any way 

detrimental to our interest or shared with outside parties. Technical Tips/ ARC6000 Programming—Dry                          Rev 2.2.2011 

Logo on console may vary due to the 

age of the console.  They work exactly 

the same regardless of logo 

Summary of Contents for TeeJet Mid-Tech ARC 6000

Page 1: ...onsole prior to jump starting welding or charging battery The TeeJet ARC 6000 User Guide is available online in pdf format at www teejet com Products Application Control and Equipment 2011 Newton Crou...

Page 2: ...oom Switch ON OFF Indicators Displays Data 1 Liquid Pressure normal pressure based spraying 2 Liquid Standard normal flow based spraying 3 Liquid Reflow used on some European sprayers 4 Granular Stand...

Page 3: ...constant from the chart Have to know chain type width plus encoder type It must match the gate height Application Rate __________ Step 5 This is your product in lbs cu ft If the product density is not...

Page 4: ...2 This is a personal choice 7 10 mph are common This number is for testing only With these selections you are now ready to enter the data into your console H I J K L Move switch down Change Console to...

Page 5: ...een will scroll through selections 4 C Stnrd 5 C SPL it 1 L PSI 2 L Stnrd 3 L rEFLO Liquid Dry Be sure you are in the correct mode These selections look very similar Look for the C 2011 Newton Crouch...

Page 6: ...crease accordingly The number one should light red This is your dry swath Numbers 2 9 should have a ZERO value 1 your swath is entered in INCHES 50 ft swath 600 in 60 ft swath 720 in 80 ft swath 960 i...

Page 7: ...t number for your load This is the amount of deviation from your desired application rate that you allow It changes in increments of 10 Usually it is not desirable to have your spread rate deviate sub...

Page 8: ...r that threshold is passed It is usually 1 acre Twist Display Selector to Total Area Display will show Err This number is a cumulative total of all jobs you have spread since you last cleared the cons...

Page 9: ...onveyor interface master on Number 1 lit with single switch is dry swath Must fill out all Slots 2 9 with a value 0 TOTAL APPLIED D Spreader Constant must match gate height for unit GET OUT of the tru...

Reviews: