background image

 7 

Using switch labeled INC. / DEC.   Push 
switch up or down .  Number will increase 
or decrease accordingly. 

Twist Display Selector to 

Total Applied

 

The spreader constant number must be 
checked.  The  gate height must match the 
constant chosen. 
 
Using conveyor width & type plus encoder 
type NCI has a chart to obtain this number. 

Twist Display Selector to  

Application Rate

 

Using switch labeled INC. / DEC.   Push switch up or 
down .  Number will increase or decrease accordingly. 

Product density should be measured & entered 
with each load.   
 
NCI sells a density scale 
(SM-DS-50895)that will 
give you the correct     
number for your load. 

This is the amount of deviation from your 
desired application rate that you allow.  It 
changes in increments of 10. 

 
Usually, it is not desirable to have your 
spread rate deviate substantially. 

Twist Display Selector to 

% Rate

 

This is your product density entered in lbs/cu ft.   

Incorrect product density will cause your application rate to be incorrect 

ALWAYS return to 100% in the Operate Mode or your entire job will be incorrect!! 

©2011 Newton Crouch Inc.  This information is the property of Newton Crouch Inc. and is loaned confidentially to our customer for his sole use.  It must not be used in any way 

detrimental to our interest or shared with outside parties. Technical Tips/ ARC6000 Programming—Dry                          Rev 2.2.2011 

This setting allows for 

110% I

—the desired rate 

plus 10%  

Summary of Contents for TeeJet Mid-Tech ARC 6000

Page 1: ...onsole prior to jump starting welding or charging battery The TeeJet ARC 6000 User Guide is available online in pdf format at www teejet com Products Application Control and Equipment 2011 Newton Crou...

Page 2: ...oom Switch ON OFF Indicators Displays Data 1 Liquid Pressure normal pressure based spraying 2 Liquid Standard normal flow based spraying 3 Liquid Reflow used on some European sprayers 4 Granular Stand...

Page 3: ...constant from the chart Have to know chain type width plus encoder type It must match the gate height Application Rate __________ Step 5 This is your product in lbs cu ft If the product density is not...

Page 4: ...2 This is a personal choice 7 10 mph are common This number is for testing only With these selections you are now ready to enter the data into your console H I J K L Move switch down Change Console to...

Page 5: ...een will scroll through selections 4 C Stnrd 5 C SPL it 1 L PSI 2 L Stnrd 3 L rEFLO Liquid Dry Be sure you are in the correct mode These selections look very similar Look for the C 2011 Newton Crouch...

Page 6: ...crease accordingly The number one should light red This is your dry swath Numbers 2 9 should have a ZERO value 1 your swath is entered in INCHES 50 ft swath 600 in 60 ft swath 720 in 80 ft swath 960 i...

Page 7: ...t number for your load This is the amount of deviation from your desired application rate that you allow It changes in increments of 10 Usually it is not desirable to have your spread rate deviate sub...

Page 8: ...r that threshold is passed It is usually 1 acre Twist Display Selector to Total Area Display will show Err This number is a cumulative total of all jobs you have spread since you last cleared the cons...

Page 9: ...onveyor interface master on Number 1 lit with single switch is dry swath Must fill out all Slots 2 9 with a value 0 TOTAL APPLIED D Spreader Constant must match gate height for unit GET OUT of the tru...

Reviews: