background image

Getting Started 

Please note: 

 

This product is only compatible with ¾-inch standard yard 
hydrants with a minimum bury depth of 3’. 

 

DO NOT back-fill around the YHME without the yard hydrant first 
being installed.

 The hydrant needs to be in place in order to 

maintain correct positioning of all components during the back-fill 
process; the PVC pull-pipe included with the YHME is for shipping 
purposes only.

 

 

DO NOT connect and tighten any water supply fittings to the 
YHME until your yard hydrant is installed.

 Doing so could cause 

the stationary portion of the pitless adapter to turn inside the YHME 
and become misaligned. 

 

We recommend using at least 2’ of PEX pipe or soft copper pipe to 
connect the pitless adapter to the water supply line. This will insure 
that your connection to the pitless adapter will not be put under 
strain in the case of shifting soil.  
 

Additional Supplies Needed: 

 

New ¾-inch standard yard hydrant 

 

Minimum of 2 feet of PEX pipe or soft copper pipe and fittings to 
connect to YHME’s 1-inch female threaded inlet 

 

Pipe thread sealant 

 

Flashlight 

 

Shovel 

 

Gravel for bottom of YHME perforated seepage area 

 

 

 

 

 
 

 
 
 
Installation Procedure: 

 

1.

 

Excavate the ditch to the required water supply depth

. To 

accommodate the perforated drainage section of the YHME, a 
hole will need to be dug approximately 8 inches deeper than the 
water line depth for the YHME to set in. Place a small amount of 
gravel in the bottom of this hole.

  

2.

 

Remove the top cap from the YHME (will be re-assembled at step 
#12) using the hex (Allen) wrench provided. 

3.

 

Pull the ¾-inch PVC riser pipe STRAIGHT up and out from inside the 
YHME riser.  DO NOT attempt to unscrew the PVC pipe while still in 
the YHME casing. The removable portion of the pitless adapter will 
come out as well. 

4.

 

Unscrew the ¾-inch PVC pipe from the brass nipple connected to the 
removable portion of the pitless adapter and discard the PVC pipe. 

5.

 

Use pipe sealant on the threads of the brass nipple and screw the 
nipple, with the removable portion of the pitless adapter, into the 
bottom of the new hydrant. As you tighten this fitting note what 
direction you want your hydrant to face. 

6.

 

While the YHME is in its shortest position, insert the new yard 
hydrant with the removable portion of the pitless adapter assembly 
down into the YHME body. The removable portion of the pitless 
adapter must align with the stationary portion of the pitless adapter 
mounted in the bottom of the YHME body and then slide into place. A 
flashlight may be needed to see down into the bottom of the YHME 
casing while completing this step.  

7.

 

To ensure that the o-ring in the pitless adapter has sealed properly, 
rotate the yard hydrant side to side before re-centering it within the 
YHME casing.  

 

 

Reviews: