15
•
VOLTMETER
The Micro700 can also function as a voltmeter. The operating range
of the voltmeter is 0 to 30 volts.
IMPORTANT:
If the Micro700 is connected to a voltage source
greater than 30 volts, the circuit board might be damaged.
To use the voltmeter function, press and hold the MENU button.
Scroll to the VOLTMETER option and press ENTER.
Use the red and black clamps as probes. If the analyzer is connected
in reverse polarity it will not detect voltage and will turn itself off.
To turn off the voltmeter function, disconnect from the voltage source
and press the MENU button. To conserve its 9-volt battery, the
analyzer will automatically shut off if 0 Vdc is detected for 20
seconds.
SET ADDRESS
This option enables you to include your shop name and address on
test result printouts.
Scroll to the SET ADDRESS option and press ENTER. The analyzer
will prompt you through each line of the name and address. Use the
ARROW buttons to change characters. Use the ENTER and BACK
buttons to move to the next or previous position.
PERFORM TEST
This option enables you to begin a new test without disconnecting
from the battery.