30
•
NOTE:
The actual time needed to charge the battery
may be less than the estimated time depending on
the battery’s charge acceptance.
When the battery requires testing, the display alternates
between the CHARGING and TESTING screens. The TESTING
screens represent a two-step process:
Step 1: The GR8 applies an electrical load and tests the bat-
tery’s response.
Step 2: The GR8 measures the battery’s CCA.
Recovery Mode
In some cases the GR8 may give you the option of selecting
Recovery Mode before displaying the final results.
Recovery
Mode optimizes the charge for a hard-to-charge battery.
To continue the charge session, press the
YES
soft key in
response to:
The maximum charge time in Recovery Mode is three hours,
although most batteries will finish charging sooner. During
Recovery Mode the charger continuously analyzes the battery
to make a decision as quickly as possible.
If you select
NO
, the charge session aborts (stops) and you will
not be able to obtain a test code.
If you make no selection within two minutes, the GR8
automatically proceeds to Recovery Mode.
Aborting a Charge Session
If you need to abort the charging session, press the
STOP
key
.
You will not be able to obtain a test code for an uncompleted
charge. After aborting, select NEXT to return to the Main
Menu.
Completing a Charge Session
The charge session is complete when the proper amount of
charge is put back into the battery or the remaining estimated
time to charge counts down to zero.
If the GR8 finds that the battery is bad before the end of the
estimated time to charge, it displays the decision REPLACE
BATTERY or REPLACE-BAD CELL and the results.
When the decision is GOOD BATTERY, the GR8 gives you
the option of topping off the battery’s charge level before it
displays the results.
Top-Off Mode
Top-off charging fills a good battery to capacity after a
completed charge session. The GR8 gives you the option of
selecting
YES
to proceed to Top-Off at any time or
NO
to
display the results.
If you make no selection within two minutes, the charger
automatically begins Top-Off Mode.
You have the option of stopping Top-Off Mode at any time by
pressing the
STOP
key or allowing the GR8 to complete the
charging. When Top-Off Mode is complete, the alarm
sounds
every 30 seconds until you press
STOP
.
Press the
NEXT
soft key to display the final results.
Total charging time
Amp hours replaced
Charging mode
Chapter 6: Charging Menu—Diagnostic Charging
GR8 1100
Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527
www.midtronics.com
Summary of Contents for GR8 1100
Page 2: ...This page intentionally left blank...