29
•
5.
Use the
UP
(
p
) or
DOWN
(
q
)
ARROW
key to select the
battery type.
1
REGULAR FLOODED
2
AGM
3
AGM SPIRAL
6. Use the
UP
(
p
) or
DOWN
(
q
)
ARROW
key to select a
testing/charging option, or press the corresponding nu-
merical key to move the dot to the option button of your
choice.
TEST USING:
1
CCA
4
SAE
2
JIS
5
IEC
3
DIN
6
EN
IMPORTANT:
It is important to input the correct
charge parameters. If you use the wrong param-
eters, an inaccurate result will occur.
7. If C
CA, use the keypad to enter the value, or scroll
to the value with t
he
UP/DOWN ARROW
keys. Press
SELECT
.
500
CCA
OR
If JIS, select the JIS number.
26A17
26A19
26B17
28A19
Initial analysis
When you select the last charge parameter the GR8 begins the
initial battery analysis. The progress of the analysis is shown by
the left to right movement of a progress bar.
If additional testing is required, progress is shown by the
clockwise fill of a pie chart.
Deep Scan Test
In some cases the GR8 may need to further analyze a deeply
discharged battery to determine whether the battery should be
replaced, or if it can possibly be recovered. It will then conduct a
Deep Scan Test of the battery
for a few seconds while displaying
a battery undergoing a scan. If any messages appear during the
test, refer to Chapter 10: Test Messages on page 45.
If the battery does no
t need charging, the GR8 displays the
results and its analysis, which includes the State-of-Health
(SOH). For screen illustrations and an explanation of the
results, see the next section.
Activity in title bar: CHARGING
(blinking) or TESTING
Charging voltage
Charging current
Amount of charge replaced
in amp hours
Countdown of the estimated
time needed to charge the
battery in hours, minutes, and
seconds**
Charging mode
Fills left to right as charging
progresses
Diagnostic Charging
If the GR8 determines that the battery has an i
nsufficient State-of-Charge,
it automatically begins Diagnostic Charge Mode. During
the charge session the GR8 controls t
he charging voltage, current and duration based on its continual analysis of testing and
charging data, and the selected battery parameters.
The illustration shows an example of the information displayed during
charging.
Chapter 6: Charging Menu—Diagnostic Charging
GR8 1100
Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527
www.midtronics.com