6d. Cabinet driver
6c. Control connection 0-10V - Outdoor driver
Strip the rubber jacket of the cable, expose 25 mm of
conductors. Mount the TH384 – socket connector.
Match
L
BROWN conductor (D
pole)
N
BLUE conductor (Dimming - pole)
Ground pole
with the 12 V+ wire.
Tighten the screws and pull each wire to check if they are
well clamped. Conductor colours may vary.
Remove the plastic cap to plug the control cable (3 poles,
white connector).
Insert the socket into the connector housing. Tighten the plastic nut to seal the cable with the connector
grommet.
midstreamlighting.com call +44 (0) 207 584 8310
16
17
MODUS S INSTALLATION GUIDANCE
25
Dim
+
Dim
-
12v
Outdoor layout
INPUT cable: this cable power supplies the driver. Its 3 wires have to match these connections:
Brown
L / L1
Blue
N / L2
Yellow&Green
Ground
OUTPUT cable: this cable power supplies the floodlight. This cable has 2 wires: brown (+) and blue (-). The
connection has to be done in such a way that the 2 wires match these poles on the floodlight connector on the top of
the mast:
Brown
L
Blue
N
OUTPUT cable: this cable power supplies the floodlight. This cable has 2 wires: brown (+) and blue (-). The
connection has to be done in such a way that the 2 wires match these poles on the floodlight connector on the top of
the mast:
Purple
D
Grey
Dimming -
Black&White
12 V Auxiliary output voltage (only if needed)
Cabinet layout
Input cable (mains)
Control cable
Output cable