Midstream Modus S 1100 Installation Guidance Download Page 4

midstreamlighting.com   call +44 (0) 207 584 8310

7

1

A

B

C

D

E

F

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

E

F

D

C

B

A

MIDSTREAM

478

432

593

398

152

230

182

202

176

16

96.2

30

90

17

21

REV.

DOCUMENT N°

DESCRIPTION 

ZONE DATE

DRAWN

CHECKED

This drawing is property of MIDSTREAM LIGHTING LTD.  All rights reserved the partial or total reproduction of it is forbidden without express consent.

MIDSTREAM LIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44  207 584 8310

Drawing Number

MODUS_R_S900_A0_ANG

24-Jul-20

Modus Sport

Date

1:10

1

/

1

Description

Scale

Sheet

FG

PC

MIDSTREAM

20 Kg

0

Drawing by

Checked by

Approved by

Weight 

Rev.

EPA: 0,203 m 2

MASS: 20 Kg

DRIVERS DRAWINGS, SCALE 1:5

Outdoor drive; Cabinet driver 

is the same without metalwork

Visors to 

be mounted 

with 4x M6 

screws each 

along with 

serrated 

washers

SCALE 1:5

5. Visor mounting

Secure visors

Mount a visor on each LED module. The visor must be 
secured with the supplied screws along with the serrated 
washers as shown.

Tightening torque: 7-8 Nm. 

The shape of the visors may vary.

Securing the cable

The cables for the floodlight connection and power 
connection must have 3 conductors (max. diameter 
13 mm). Maximum conductors section is 1.5 mm

2

 for 

floodlight connector, 4 mm

2

 for power connection).

Use a cable with 2 conductors for 0-10 V, DALI control 
connection (max. diameter 12 mm).

On floodlights with an outdoor driver, secure the control 
plug with the supplied closure cap when the control 
system is not in use.

A  Control cable – 0-10 V, DALI (not supplied)

B  Mains cable – power connection (not supplied)

Important

Mount the shortest visor on the bottom module and the  
longest visor on the top module, to avoid blocking light.

To protect the floodlight and its components and avoid 

scratching, please lay the luminaire on the packaging  

foam when mounting the visors or the bracket.

Flood light connection  

(cable not supplied)

6. Electrical connection

Use a main circuit breaker 

with a rated current of  

at least 10A

Do not apply mains voltage 

through the control system  

cable. This will damage  

the luminaire.

B

A

2. Insert screws

Insert each screw with its plain washer and spring washer 
through the central hole of the fitting bracket flange and 
slightly tighten.

You will need to rotate the bracket with ease to adjust the 
tilt.

4. Mounting

When the LED luminaire installation has been completed, 
secure the floodlight to the mounting structure via the 
safety cable.

Connect the safety cable to the holding frame with the 
supplied carabiner hook.

1. Angled bracket

The floodlight is equipped with an angled bracket that 
has a central hole for an M20 screw (tightening torque 
250 Nm) and two slots for M16 screws -tightening 
torque: 150 Nm.

3. Adjusting angle

The LED Luminaire can be tilted for ±20° using the scale 
of 5° intervals when the longer notch sits in one of the 
bottom land of the gear. If the bracket is rotated and the 
shorter notch sits in one of the bottom land of the gear, 
tilt has increased/decreased by 2,5°.

Once the tilting operation is complete, tighten and lock 
the screws. Tightening torque: 60 Nm

SCALE  1:4

SEE DETAIL  

A

Date

Revision

Sheet

MIDSTREAM LIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44  207 584 8310

This drawing is property of MIDSTREAM LIGHTING Ltd. All rights reserved the partial or total reproduction of it is forbidden without express consent.

Drawing by

Checked by

Approved by

MIDSTREAM

MC

PC

HM = HIGH MAST

E

av

 = AVERAGE Lux LEVEL

u

0

 = UNIFORMITY E

min

 / E

av

Total HM (All) - 8 with height of 16m

Total Luminaires (All) - 16 x Modus S1100 MS

- 08 x Modus S1100 WS

2/3

00

06/04/2021

ML0556 - Hymers College - Mounting Instructions - Ref. to REV03 - Luminaire Details

horizontal reference

Visors parallel to

the ground: 0° tilt

Tilt is defined as

the angle between

the horizontal

reference and the

visors' edge

Fitting bracket has 2

holes that will set a

reference when aligned

to the longer notches

on the side of the

floodlight.

Those reference set the

tilt at 0°. Reference

notch can vary

according to mounting

layout.

SEE DETAIL  A

SEE DETAIL  B

The loop allows only

+/-20° tilts

2.5° resolution check

Range of tilt allowed is +/-20°

Every round sets a 5° interval, but resolution of bracket can be as

precise as 2,5°.

The angular rotation between a crest and a round is exactly 2,5°.

When the longer notch sits in a round, tilt is a multiple of 5°, but then

if the bracket is rotated to center the shorter notch in a round, tilt

has increased / decreased by 2,5°.

2.5°

Side View of the Luminaire with a Tilt

of 0.0°

DETAIL A

DETAIL B

6

MODUS S INSTALLATION GUIDANCE

4. Bracket mounting and aiming

Use A2-80 stainless steel bolts or 8.8 class 

steel bolts with hot dip galvanised coating

Do not use percussion drills

Summary of Contents for Modus S 1100

Page 1: ...Modus S Series INSTALLATION GUIDANCE v3 0...

Page 2: ...important information on safe operation of the Luminaire Read and follow all safety notes and all instructions Save this manual for future reference Make sure that it is available to all persons using...

Page 3: ...d experience may use this device The minimum safety distance from illuminated object to avoid any damages is 1 m midstreamlighting com call 44 0 207 584 8310 5 Modus S LED floodlight Remote driver x1...

Page 4: ...ped with an angled bracket that has a central hole for an M20 screw tightening torque 250 Nm and two slots for M16 screws tightening torque 150 Nm 3 Adjusting angle The LED Luminaire can be tilted for...

Page 5: ...he gasket remove cable gland nut first midstreamlighting com call 44 0 207 584 8310 8 9 MODUS S INSTALLATION GUIDANCE SCALE 1 1 SEE DETAIL A 6a Floodlight connection outdoor driver Unscrew the cover U...

Page 6: ...the connection If unlocking is required use a screwdriver to pull the clip to an unlocked position Warning Do not pull the cables during installation Do not bend the cables more than the minimum bend...

Page 7: ...the mains cable through the cable gland without the adapter Connect the YELLOW GREEN wire to the 5 way WAGO terminal Close the void position as well even if there is no wire connected Connect the BRO...

Page 8: ...he cover back on to the driver unit and the cap on the control plug if not needed Strip the rubber jacket of the cable expose 25 mm of conductors Mount the TH384 socket connector Match L RED conductor...

Page 9: ...DUS S INSTALLATION GUIDANCE 25 Dim Dim 12v Outdoor layout INPUT cable this cable power supplies the driver Its 3 wires have to match these connections Brown L L1 Blue N L2 Yellow Green Ground OUTPUT c...

Page 10: ...er Weight 20kg 9kg 6 5kg Windage 0 203m2 at 220 V ac input 25 C cold start 10 Ipk 10 Ipk Modus S Floodlight Modus S Outdoor driver cabinet driver is the same without metalwork 280 x 230 x 76 mm midstr...

Page 11: ...ation guides European HQ Midstream Ltd Wessex House 1 Chesham Street London SW1X 8ND United Kingdom Telephone 44 207 584 8310 Email info midstreamlighting com US HQ Midstream Lighting Ltd 66 West Flag...

Reviews: