Midstream Modus 450 Installation Guidance Download Page 5

Tighten the nut

Tighten the nut using a 21 mm wrench

Connect the power cable

Connect the socket to the plug on the LED luminaire and 
tighten the housing to ensure IP68 protection. Test the 
luminaire before attaching it to the final connection point.

Connect the power cable to the connector with 'POWER' 
sticker on it, and control cable to the connector with 
'CONTROL' sticker on it.

midstreamlighting.com   call +44 (0) 207 584 8310

8

9

MODUS 450 INSTALLATION GUIDANCE

6. Electrical connection

6. Electrical connection

Connector mounting

To mount the connector on the cable, remove the cable sheath for 25 mm. The wires do not need to be stripped 
because the connector is equipped with piercing screws. If the cable diameter is great than 9 mm remove the inside 
part of the grommet. To remove the gasket, remove cable gland nut first. Insert the cable through the socket housing 
of the connector.

Wiring instructions

Insert each wire into the socket terminal, matching wire 
colour with the 'L', 'N' and 'GND' symbol on the socket 
and tighten the screws. Match:

Mains cable

 

Live  

 

        

 

BROWN wire 

Neutral   

        

 

BLUE wire  

Earth symbol             

 

YELLOW/GREEN wire. 

Dali control cable

Live  

 

  

DALI+ 

Neutral   

  

DALI-

0-10 V control cable

Live  

 

  

 

Neutral   

  

Control- 

Earth symbol 

 

12V aux (only if needed)

Insert the socket into the housing until the inner part 
'clicks' in and then insert the gasket.

Self-piercing

DA1

DA2

++

=

DA1

DA2

++

=

DALI control 2 pole

0-10V control  
and power 3 pole

Reviews: