Midstream Modus 450 Installation Guidance Download Page 4

2. Insert screws

Insert each screw with its plain washer and spring washer 
through the central hole of the fitting bracket flange and 
slightly tighten.

You will need to be able to rotate the bracket with ease to 
adjust the tilt.

4. Mounting

When the LED luminaire installation has been completed, 
secure the floodlight to the mounting structure via the 
safety cable.

Connect the safety cable to the holding frame with the 
supplied carabiner hook

.

1. Angled bracket

The floodlight is equipped with an angled bracket that 
has a central hole for an M20 screw (tightening torque 
250 Nm) and two slots for M12 screws (tightening torque: 
80 Nm). Bracket has 2 positioning layouts.

3. Adjusting angle

The LED luminaire can be tilted at 5° intervals using the
notches on the frame and the references on the bracket.

Once the tilting operation is complete, tighten and lock 
the screws (tightening torque: 50 Nm).

56.0

1

A 3.00

22.0

2

A 3.00

22.0

 

A 3.00

56.0

 

A 3.00

SCALE  1:1

SEE DETAIL  

A

midstreamlighting.com   call +44 (0) 207 584 8310

6

7

MODUS 450 INSTALLATION GUIDANCE

4. Bracket mounting and aiming

Use A2-80 stainless steel bolts or 8.8 class 

steel bolts with hot dip galvanised coating

Do not use percussion drills

4.9°

56.0

1

A 3.00

22.0

2

A 3.00

22.0

 

A 3.00

56.0

 

A 3.00

SCALE  1:1

SEE DETAIL  

A

5. Visor mounting

Secure visor

Mount the visor on the LED module. The 
visor must be secured with the supplied 
screws along with the serrated washers 
as shown.

Tightening torque: 7-8 Nm. 

The shape of the visors may vary.

Power plug 

The cable for floodlight power connection must have 
3 conductors (max. diameter 12 mm, max. section 
1,5 mm

2

). This should be connected to the white plug 

labelled 'power'. 

Control plug 

Use a cable with 2 conductors for DALI control 
connection (max. diameter 12 mm, max section 1,5 
mm

2

). This should be connected to the yellow plug, 

labelled 'control'.

Use a cable with 3 conductors for 0-10 V control
connection (max. diameter 12 mm, max section 1,5 
mm

2

).

This should be connected to the white plug, labelled 
'control'.

6. Electrical connection

Use a main circuit breaker 

with a rated current of  

at least 16 A

Do not apply mains voltage 

through the control sytem  

cable. This will damage  

the luminaire.

Control 

connector 

yellow (DALI),  

or white (0-10V).

Keep closed 

with cap if

not in use

Power 

connector 

(white) 