Mido RA0713 User Manual Download Page 4

3

 

5. Data Report

The device will immediately send a version package Report and a report data with temperature and humidity and voltage 

Values. The device sends data in the default configuration before any configuration is done.

 

ReportMaxTime: 

RA0713_ RA0713Y 

is 180s and RA72613 is 900s; (subject to factory 

settings) ReportMinTime: 30s; ReportChange: 0;

 

Note: The device send data cycle has been programmed to be correct.

 

The interval between two reports must be the maximum time

 

The RA0713_R72613_RA0713Y device does not support the ReportChange function, that is, the function is 

invalid. The sent report data string is always sent according to the ReportMaxTime period (starting to the end of the 

first data as a period).

 

The data of the device Report is: soil moisture value, ReportType count = 1;

 

Note: 1. The value of ReportMaxTime is greater than (ReportType count *ReportM 10 units: seconds);

 

2. The device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, the device can

also perform a report according to the cycle time of the TxPeriod value; and at a certain time, the report period is

 

ReportMaxTime or TxPeriod, depending on which cycle time is configured last time;

 

3. After pressing the button, the device needs 35 seconds to process the sensor information, please be patient.

The data parsing reported by the device is referenced by the 

MiDoMet

 LoraWAN Application Command document 

and 

www.midosmart.com

Report Configuration Example:

Description

 

Device

 

CmdID

 

DeviceTy 

pe

 

PayLoadData

 

ConfigReportRe 

q

 

RA07

 

Series/

 

R726

 

Series/

 

R727

 

Series

 

0x01

 

0x05/0x0

 

9/0x0D

 

MinTime(2 

bytes

 

Unit:s)

 

MaxTime(2by 

tes Unit:s)

 

Reserved  (5Bytes,Fixed 0x00)

 

ConfigReportRs 

p

 

0x81

 

Status(0x00

 

_success)

 

Reserved (8Bytes,Fixed 0x00)

 

ReadConfigRepo 

rtReq

 

0x02

 

Reserved (9Bytes,Fixed 0x00)

 

ReadConfigRepo 

rtRsp

 

0x82

 

MinTime(2 

bytes

 

Unit:s)

 

MaxTime(2by 

tes Unit:s)

 

Reserved

 

(1) Configure RA0713 device parameters MinTime = 30s, MaxTime

= 120s (120>30*1+10) Downlink: 0105001E00780000000000

Device returns:

8105000000000000000000 (configuration is successful)

 

8105010000000000000000 (configuration failed)

 

(2)

 

Read RA0713 device parameters Downlink: 

0205000000000000000000 Device returns:

 

8205001E00780000000000 (device current parameter)

 

Data report configuration and sending period are as following:

 

Min Interval

 

(Unit:second)

 

Max Interval

 

(Unit:second)

 

Reportable

 

Change

 

Current 

Change≥

 

Change

 

Reportable

 

Current  Change

 

Change

 

 

Reportable

Any 

number

 

1~65535

 

between

 

Any number between

 

1~65535

 

Can not be 0.

 

Report per Min 

Interval

 

Report per Max 

Interval

 

Example#1 

based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V

 

Summary of Contents for RA0713

Page 1: ...The RA0713_R72613_RA0713Y can be connected to the EC_5 sensor and the value collected by the sensor is reported to the corresponding gateway LoRa Wireless Technology LoRa is a wireless communication...

Page 2: ...External soil moisture sensor subject to the actual object 3 Main Features Compatible with LoRaWAN RA0713 RA0713Y apply DC 12V adapter R72613 applies solar and rechargeable lithium batteries 4 Set up...

Page 3: ...ress and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes for 20 times success The green indicator remains off fail Press once The device is in the network the green...

Page 4: ...button the device needs 35 seconds to process the sensor information please be patient The data parsing reported by the device is referenced by the MiDoMet LoraWAN Application Command document and ww...

Page 5: ...is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another c...

Page 6: ...rechargeable 18650 lithium battery a total of 3 sections a single rechargeable lithium battery voltage 3 7V capacity recommended 5000mah the installation of rechargeable lithium battery steps are as f...

Page 7: ...lastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devi...

Reviews: