Mido RA0713 User Manual Download Page 3

2

 

Note:

 

1.

Engineering test modes require the burning engineering test software.

2.

On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance

and other energy storage components.

Network Joining

Never joined the network

 

(Or at factory setting )

 

Turn on the device to search the network.

 

The green indicator stays on for 5 seconds: success

 

The green indicator remains off: fail

 

Had joined the network

 

(Not at factory setting.)

 

Turn on the device to search the previous network.

 

The green indicator stays on for 5 seconds: success

 

The green indicator remains off: fail

 

Fail to join the network

 

(when the device is on)

 

First two mins: wake up every 15 seconds to send request.

 

After two mins: enter sleeping mode and wake up every 15 minutes to send 

request. Note: Suggest to remove batteries if the device is not used to save power. 

Suggest to check the device verification information on the gateway or consult your 

platform server provider.

 

Function Key

Press and hold for 5 seconds

 

Restore to factory setting / Turn off

 

The green indicator flashes for 20 times: success

 

The green indicator remains off: fail

 

Press once

 

The device is in the network: the green indicator flashes once and the device sends a data report

 

The device is not in the network: green indicator remains off

 

Low Voltage Threshold

Low Voltage Threshold

 

10.5 V

 

Restore to Factory Setting

 

Instruction

 

RA0713_R72613_RA0713Y has a network information memory function saving function when power-down. 

This function is turned off by default, that is, it will be re-joined every time it is powered back on. This function 

can be turned on by the ResumeNetOnOff command. At this time, each time the power is rewritten, the last 

network joining information will be recorded (including saving the network address information assigned to it, 

etc., if you want to join a new network, you need to perform a factory resetting operation first.) 

It will not 

be re-joined the previous network.

 

Operation

 

1.

Press and hold the button for 5 seconds and release (the binding button is released when the LED

flashes), and the LED flashes for 20 times.
2.

The device will automatically restart to re-joining.

Summary of Contents for RA0713

Page 1: ...The RA0713_R72613_RA0713Y can be connected to the EC_5 sensor and the value collected by the sensor is reported to the corresponding gateway LoRa Wireless Technology LoRa is a wireless communication...

Page 2: ...External soil moisture sensor subject to the actual object 3 Main Features Compatible with LoRaWAN RA0713 RA0713Y apply DC 12V adapter R72613 applies solar and rechargeable lithium batteries 4 Set up...

Page 3: ...ress and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes for 20 times success The green indicator remains off fail Press once The device is in the network the green...

Page 4: ...button the device needs 35 seconds to process the sensor information please be patient The data parsing reported by the device is referenced by the MiDoMet LoraWAN Application Command document and ww...

Page 5: ...is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another c...

Page 6: ...rechargeable 18650 lithium battery a total of 3 sections a single rechargeable lithium battery voltage 3 7V capacity recommended 5000mah the installation of rechargeable lithium battery steps are as f...

Page 7: ...lastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devi...

Reviews: