For this feature
Enter These Codes
Transmit Parameters (10 digits)
A) Trunking Delay
(0-9 seconds)
Enter a trunking delay of 0-9 seconds. This allows the radio to scan for an empty
interconnect channel.
B) Key-Up Delay
(.0-.9 seconds)
When dialing the transmitter will key, pause for the key-up delay, & then send the
tones.
C) Back Porch/Lead-Out Delay
(.0-.9 seconds)
This is a time after sending ANI that the transmitter will release PTT.
D) Single Digit Tone Time
(0.0-9.9 seconds)
Sets the length of time for any single-digit sequence during ANI or dialing.
E) COR Refresh Period
(00-99 seconds)
Sets length of time between transmission bursts. This prevents some full-duplex
systems from disconnecting during conversations.
F) COR Refresh Width
(.0-.9 seconds)
Sets width of transmission burst. This prevents some full-duplex systems from
disconnecting during conversations.
G) Dialing Enabled
(0=disabled, 1=enabled)
This enables dialing. In some systems dialing will not be desired.
H) Auto Dial Time
(0=disabled, 1-9=seconds)
This limits the time between manually-entered digits. If enabled & the user
pauses
for more than this time, the TRA will automatically send the entered sequence.
* 11
Decoding Parameters (9 digits)
A) Ring Period
(00-99 seconds)
Enter a ring period of 00-99 seconds.
B)
Horn Period
(0-9 seconds)
This sets the length of time the optional horn relay will be energized.
C)
N-Click Decode
(0=disabled, 1-9 =enabled)
The number of PTT clicks needed to activate the TRA ring tones.
D)
N-Click Timeout
(.0-.9 seconds)
Enter the maximum time allowed between clicks to activate N-Click decode.
E)
Hot Dialing Time
(0.0-9.9 seconds)
The amount of time PTT will remain up between entries.
F)
VOX Hold Timer
(.0-.9 seconds)
Amount of time that PTT will remain open on an unmodulated signal.
Recommended: .5 to .8 seconds.
G) Scan Step
(0=Step, 1=Binary)
Selects between 3-line binary scan or step scanning.
* 12
System Parameters (11 digits)
A) Queuing Signal Delay
(0-9 seconds)
The unit will monitor the channel until it has been idle for the time entered here and
then generate 3 beeps to indicate that the channel is no longer busy.
B) COR Active Input Level
(0=GND, 1=V+)
Sets COR Active logic state.
C) Squelch Active Input Level
(0=GND, 1=V+)
Sets Squelch Active logic state.
D) Busy Lockout, # Channels to Scan
(00=off, 01-16=on, # chan.)
Enables Busy Lockout and sets the number of channels to scan.
00 disables both scanning and busy lockout.
E) Scan Pulse Time/Synthesizer Lock Time
(.00-.99 seconds)
Sets length of time that scan output is active.
F) Scan COR Detect Time
(.00-.99 seconds)
Sets minimum length of time for radio to lock on to carrier.
G) Dial Tone and Talk Beep
(0=Both OFF, 1=Dial Tone Only, 2=Talk Beep Only, 3=Both ON)
Determines whether TRA internally generates dial tone and beep after dialing.
H) System Type
(0=Duplex, 1=Half-duplex, 2=Simplex)
* 13
System Timers (9 digits)
A) Call Limit Time
(000-999 seconds; 000=disabled)
Sets the maximum length of time before disconnect.
B) VOX Keyup Limit
(00-99 seconds; 00=disabled)
Length of time TRA will generate PTT with continuous voice input, before timing
out.
C) No VOX Activity Disconnect Time
(00-99 seconds)
Length of time before disconnect when no voice is detected.
D) Call Reminder Interval
(00-99 seconds)
If call is not answered by user, a reminder ring is generated at the interval set
here.
* 14
Enter *00 to exit programming mode (unit will emit long beep)
Summary of Contents for TRA
Page 16: ...This page intentionally left blank...
Page 17: ......
Page 18: ...This page intentionally left blank...
Page 19: ......
Page 20: ......