background image

 

 

13

T

ABLE 

8:

 

GE

 

T

YPE 

99

 

T

ABLE 

G

ROUP

 

A

 B C 

T

ONE 

# F

REQ

 

F

REQ

 

F

REQ

 

592.5 607.5 712.5 

757.5 787.5 772.5 

802.5 832.5 817.5 

847.5 877.5 862.5 

892.5 922.5 907.5 

937.5 967.5 952.5 

547.5 517.5 532.5 

727.5 562.5 577.5 

637.5 697.5 622.5 

682.5 652.5 667.5 

D

IA

 742.5

 

H

Z

 

 

 

T

ABLE 

9:

 

GE Type 99 Table II 

100’

S

 

T

ONE 

R

EED 

G

ROUPS 

F

OR

 

D

IGIT

 

1

ST 

T

ONE

 

2

ND 

T

ONE

 

A A 

B A 

B B 

A B 

C C 

C A 

C B 

A C 

B C 

 

T

ABLE 

10:

 

R

EACH 

T

WO

-T

ONE 

S

EQUENTIAL 

--

 

F

AST OR 

S

LOW

 

1

ST 

D

IGIT 

OF 

C

ODE

 

G

ROUP FOR 

1

ST 

T

ONE

 

G

ROUP FOR 

2

ND 

T

ONE

 

A C 

C A 

B D 

D B 

A D 

D A 

A E 

E A 

B E 

E B 

 

 

T

ABLE 

11:

 

R

EACH 

T

WO

-T

ONE 

&

 

S

INGLE 

T

ONE 

P

AGING 

F

REQUENCIES

 

T

ONE

 

G

ROUP 

A G

ROUP 

B G

ROUP 

C G

ROUP 

D G

ROUP 

N

UM

 

C

HN

 

F

REQ

 

C

HN

 

F

REQ

 

C

HN

 

F

REQ

 

C

HN

 

F

REQ

 

C

HN

 

F

REQ

 

11 2704 21 1912 26 1608 36 1137 46  804 

12 2612 22 1847 67 1553 37 1098 47  776 

13 2523 23 1784 68 1500 38 1061 48  750 

14 2437 24 1723 69 1449 39 1025 49  725 

15 2354 25 1664 30 1400 40  990  50  700 

16 2274 26 1608 31 1352 41  956  51  676 

17 2196 27 1553 32 1306 42  923  52  653 

18 2121 28 1500 33 1261 43  892  53  631 

19 2049 29 1449 34 1219 44  862  54  609 

20 1980 30 1400 35 1177 45  832  55  588 

 

 
 

T

ABLE 

12:

 

D

IAL 

T

ONE 

&

 

T

ALK 

B

EEP

 

D

IGIT

 

D

IAL 

T

ONE

 

T

ALK 

B

EEP

 

OFF OFF 

ON OFF 

OFF ON 

ON ON 

Summary of Contents for TRA

Page 1: ...LEPHONE TO RADIO ADAPTER INSTRUCTION MANUAL Manual Revision 2006 10 31 Software Version 4 2 Higher 1 American Communication Systems Discover the Power of Communications TO ORDER VISIT http www ameradi...

Page 2: ...e 2 Band Width Motorola Two Tone 1 3 Band Width General Electric Two Tone 1 6 Band Width Reach 1 7 COR Click Counter 1 9 Click Timeout 0 9 seconds Outputs Ringing Output 33 Hz 70V RMS Ringing Period 2...

Page 3: ...rity is set by selecting polarity of squelch diode D3 using JU7 Resistor R88 can be changed to provide more or less current Do not conflict with grey lead This lead is not necessary for the TRA to fun...

Page 4: ...ndicating to the user that he can now give a voice message The user can stay on line at this point and talk to the unit they called provided they called a talk back paging portable If the user called...

Page 5: ...f decoding a phone number in order to reset the deadbeat disable feature 3 2 Connect Disconnect ANI The Automatic Number Identification locations contain the connect and disconnect ANI sequences There...

Page 6: ...a channel with an interconnect for TRA to Landline conversations Front Porch Lead In Delay This determines the period of time the TRA will wait with no modulation after applying PTT and before encodin...

Page 7: ...to the next channel or the Least Significant Bit LSB of a binary address See installation section for the Violet Wire This can be wired to the channel advance button on many synthesized radios or to...

Page 8: ...ram the connect ANI with the number 12A it would be necessary to enter the following sequence 1 2 flash 2 flash 04 4 3 Programming the Memory Dial Numbers Press and hold it down while taking the phone...

Page 9: ...ull between a low frequency howl and a high frequency howl Set the hybrid balance pot in the quiet zone between the two howls then turn back down the receive input and the ear piece levels according t...

Page 10: ...is needed The horn transistor Q10 is a VMOS power FET and provides a momentary ground to honk the horn for the time programmed in Horn Period Channel Scanning There are two types of channel scanning o...

Page 11: ...CODES TIMINGS TONE CODE EUROPEAN FIVE SIX TONE FREQUENCIES IN HZ MOTOROLA NUMBER DIGIT EEA CCIR ZVEI DZVEI DDZVEI NATEL EIA MODAT TONE 0 0 1981 1981 2400 2200 2400 1633 600 637 5 TONE 1 1 1124 1124 1...

Page 12: ...11 11 11 11 23 23 23 24 24 25 34 34 35 46 2 22 22 22 22 22 13 13 13 14 14 15 22 22 22 22 22 22 43 43 53 64 3 33 33 12 12 12 33 33 33 41 41 51 33 33 33 42 42 52 33 33 33 56 4 44 12 44 15 21 44 31 31 4...

Page 13: ...ONE 1 A C 2 C A 3 B D 4 D B 5 A D 6 D A 7 A E 8 E A 9 B E 0 E B TABLE 11 REACH TWO TONE SINGLE TONE PAGING FREQUENCIES TONE GROUP A GROUP B GROUP C GROUP D GROUP E NUM CHN FREQ CHN FREQ CHN FREQ CHN F...

Page 14: ...ble 4 C Time 1 0 000 9 999 seconds Enter the desired time for the first tone This separate timing makes possible a preamble tone If nothing is entered industry standard timings will be used D Time 2 0...

Page 15: ...t Dialing Time 0 0 9 9 seconds The amount of time PTT will remain up between entries F VOX Hold Timer 0 9 seconds Amount of time that PTT will remain open on an unmodulated signal Recommended 5 to 8 s...

Page 16: ...This page intentionally left blank...

Page 17: ......

Page 18: ...This page intentionally left blank...

Page 19: ......

Page 20: ......

Reviews: