5.5.4.6.2 2
nd
Tone Time field
Enter the duration of the 2
nd
tone in milliseconds. In the
PLECTRON fast format, this is 250 ms. All 4 digits
must be entered.
Range:
0000 to 9999 milliseconds
5.5.4.7 DTMF
type
5.5.4.7.1 On Time field
Enter the tone on-time. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
5.5.4.7.2 Gap Time field
Enter the gap time between tones. All 4 digits must be
entered.
Range:
0000 to 9999 milliseconds
5.5.4.8 POCSAG
type
5.5.4.8.1 Pager Display field
Set the display type of the pager.
NUMERIC
Numeric only pager.
ALPHA
Alphanumeric pager.
5.5.4.8.2 Baud Rate field
Set the baud rate of the pager.
512
1200
2400
5.5.4.8.3 Invert field
If Invert is on, the POCSAG data bits are inverted.
Whether or not this needs to be done will depend on
the radio and installation point. Determine this setting
by experiment.
OFF
Do not invert bits.
ON
Invert POCSAG data bits.
5.5.4.8.4 Function Bits field
The way a pager handles the function bits depends on
the specific pager. In some instances, they control
which sound the pager makes when it goes off.
00
01
10
11
5.5.4.9 Pager Profiles and Defaults
The following shows the factory default pager profile
settings that allow the PDE to function ‘out of the box’.
Please refer to section 4.2.1 for more information.
5.5.4.9.1 Profile 1
The factory default settings for this profile are as
follows:
Profile Name:
PULSE
2805
Pager Type:
Pulse
Tone
Format:
2805
Make Time:
0040
Tail Time:
1000
5.5.4.9.2 Profile 2
The factory default settings for this profile are as
follows:
Profile Name:
REACH
2-TONE
Pager Type:
2-Tone
Format:
REACH
1
st
Tone Time:
2000
2
nd
Tone Time:
0700
5.5.4.9.3 Profile 3
The factory default settings for this profile are as
follows:
Profile Name:
MOT
GENERAL
Pager Type:
2-Tone
Format:
MOT
GENERAL
1
st
Tone Time:
1000
2
nd
Tone Time:
3000
5.5.4.9.4 Profile 4
The factory default settings for this profile are as
follows:
Profile Name:
DTMF
Pager Type:
DTMF
On Time:
0050
Off Time:
0050
5.5.4.9.5 Profile 5
The factory default settings for this profile are as
follows:
Profile Name:
EIA
5-TONE
Pager Type:
5/6-Tone
Format:
EIA
1
st
Tone Time:
0033
N
th
Tone Time:
0033
5.5.4.9.6 Profile 6
The factory default settings for this profile are as
follows:
Profile Name:
EUROSIGNAL
Pager Type:
5/6-Tone
Format:
EUROSIGNAL
1
st
Tone Time:
0100
N
th
Tone Time:
0100
5.5.4.9.7 Profile 7
The factory default settings for this profile are as
follows:
Profile Name:
POCSAG-NUMERIC
Pager Type:
POCSAG
Pager Display:
NUMERIC
Baud Rate:
1200
Invert:
OFF