DDU-300 Manual Rev. 2006.02.22
Range:
00 to 99 10ths of a second (0.0 - 9.9 s)
Default: 10 10ths of a second (1.0 second)
5.6.6.3 PTT Hang Time setting
Once validation has occurred, this sets how long the
repeater will remain keyed after COR goes inactive.
Once the hang timer expires, a new validation will be
required to access the repeater.
Range:
00 to 99 10ths of a second (0.0 - 9.9 s)
Default: 20 10ths of a second (2.0 seconds)
5.6.6.4 Hang Reset setting
This setting specifies what is required to reset the PTT
hang timer before it expires. This can either be COR
or COR+ANI. When set to COR, the hang timer will be
reset if COR goes active prior to expiration, allowing
the conversation to continue without a new validation.
When set to COR+ANI, a new valid ANI will also be
required to keep the repeater open.
COR
Reset hang timer if COR goes active
before the hang time expires.
COR+ANI
Require both COR and an ANI (or
valid User ID) to reset the hang timer
before expiration.
5.6.6.5 Repeater Out setting
This setting specifies which output is used to put the
repeater into transmit mode when Repeat Control is
enabled.
PTT
PTT output used to key repeater in
Repeat Control mode.
MONITOR
MONITOR output used to key repeater
in Repeat Control mode.
5.6.7 STATUS SETUP menu
5.6.7.1 Status 0 Msg setting
There is a status message for each of the digits 0
through 9. These correspond to the first digit of a
status/location packet sent by the TVS-2. Emergency
packets always begin with the digit 9 and thus status
message 9 should always be associated with
emergency status (though the text may be changed). A
special status code is sent by the scrambler when it
has been remotely disabled. Status 10 is reserved for
this code. Each status message may be up to 10
alphanumeric characters. If not using status
messages, or if certain digits are not used, simply
leave those blank.
Range:
0-10 characters
Default: blank
5.6.7.2 Status 1 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.3 Status 2 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.4 Status 3 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.5 Status 4 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.6 Status 5 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.7 Status 6 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.8 Status 7 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.9 Status 8 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: blank
5.6.7.10 Status 9 Msg setting
See Status 0 Msg setting above.
Range:
0-10 characters
Default: EMERGENCY
5.6.7.11 Status 10 Msg setting
See Status 0 Msg setting above.