background image

The value

in the programming commands is assigned according to the following table:

cc

16

ALL

MIDI CHANNEL TABLE

MIDI CONTROL CHANGE TABLE

Decimal

0
1
2
3
4
5
6
7
8
9
10
11
12-13
14-15
16-19
20-31
32-63
64
65
66
67
68
69
70
71
72
73
74
75-79
80-83
84
85-90
91
92
93
94
95
96,97
98,99
100,101
102-119
120-127

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

Dec/

64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79

32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

96
97
98
99

100
101
102
103
104
105
106
107
108
109
110

111

16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95

48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

00
01
02
03
04
05
06
07
08
09

0A
0B
0C
0D
0E
0F

Hex

40
41
42
43
44
45
46
47
48
49

4A
4B
4C
4D
4E
4F

20
21
22
23
24
25
26
27
28
29

2A
2B
2C
2D
2E
2F

60
61
62
63
64
65
66
67
68
69

6A
6B
6C
6D
6E
6F

10
11
12
13
14
15
16
17
18
19

1A
1B
1C
1D
1E
1F

50
51
52
53
54
55
56
57
58
59

5A
5B
5C
5D
5E
5F

30
31
32
33
34
35
36
37
38
39

3A
3B
3C
3D
3E
3F

70
71
72
73
74
75
76
77
78
79

7A
7B
7C
7D
7E
7F

HEXADECIMAL CONVERSION TABLE

Hexadecimal

00
01
02
03
04
05
06
07
08
09
0A
0B
0C-0D
0E-0F
10-13
14-1F
20-3F
40
41
42
43
44
45
46
47
48
49
4A
4B-4F
50-53
54
55-5A
5B
5C
5D
5E
5F
60,61
62,63
64,65
66-77
78-7F

Control Function

Bank Select
Modulation wheel or lever
Breath Controller
Undefined
Foot controller
Portamento time
Data entry MSB
Channel Volume
Balance
Undefined
Pan
Expression Controller
Effect Controls 1-2
Undefined
General Purpose Controllers (#'s 1-4)
Undefined
LSB values for 0-31
Damper pedal (sustain)
Portamento On/Off
Sostenuto
Soft pedal
Legato Fsw (vv=00-3F: Normal, 40-7F: Legato)
Hold 2
Sound Controller 1 (default: Sound Variation)
Sound Controller 2 (default: Timbre/Harmonic Content)
Sound Controller 3 (default: Release Time)
Sound Controller 4 (default: Attack Time)
Sound Controller 5 (default: Brightness)
Sound Controllers 6-10 (no defaults)
General Purpose Controllers (#'s 5-8)
Portamento Control
Undefined
Effects 1 Depth (formerly External Effects Depth)
Effects 2 Depth (formerly Tremolo Depth)
Effects 3 Depth (formerly Chorus Depth)
Effects 4 Depth (formerly Celeste (Detune) Depth)
Effects 5 Depth (formerly Phaser Depth)
Data increment, Data decrement
Non-Registered Parameter Number LSB, MSB
Registered Parameter Number LSB, MSB
Undefined
Reserved for Channel Mode Messages

1

MIDI Channel

00

cc

2

01

3

02

4

03

5

04

6

05

7

06

8

07

9

08

10

09

11

0A

12

0B

13

0C

14

0D

15

0E

0F

7F

9

Summary of Contents for PROFESSIONAL Series

Page 1: ...OPERATING INSTRUCTIONS R8 8 OUTPUT MIDI CONTROLLED RELAY ARRAY PROFESSIONAL SERIES MIDI Solutions ...

Page 2: ...MIDI Solutions R8 Operating Instructions M426 100 2012 MIDI Solutions Inc All rights reserved MIDI Solutions Inc PO Box 3010 Vancouver BC Canada V6B 3X5 www midisolutions com ...

Page 3: ...e inserted wherever it is required in your MIDI setup Connect the MIDI Out or Thru of the sending device to the MIDI of the R8 The can be made directly to footswitch inputs or the contacts to be switched The MIDI of the R8 can be connected to the MIDI In of a receiving MIDI device or left disconnected It is recommended that the number of MIDI Solutions products powered by a single MIDI Out or Thru...

Page 4: ...tings command to the R8 prior to programming the unit to ensure that all previous settings are cleared To dump all of the R8 s current settings send it the following System Exclusive message Upon receipt of this command the R8 will dump its current settings to the MIDI Out To link together the Note and Control Change settings of a specific relay send the R8 the following programming command is set...

Page 5: ...lay produces OPEN pulse for Note Offs MIDI Note number MIDI channel see MIDI channel table at end Pulse width in 8 ms increments or 1 s increments if preceded by 00 The R8 will accept a combined total of 10 Note or Control Change settings per relay To program the R8 to close Relay6 for 10 seconds when Note On middle C is received on any MIDI channel set Relay6 relay produces CLOSED pulse for Note ...

Page 6: ...hannel see MIDI channel table at end Threshold value threshold defaults to 64 if this byte omitted Pulse width in 8 ms increments or 1 s increments if preceded by 00 The R8 will accept a combined total of 10 Note or Control Change settings per relay To program the R8 to close Relay2 when the volume on MIDI channel 16 drops below a value of 10 and open when it rises above set Relay2 relay OPEN thre...

Page 7: ...mand F0 00 00 50 26 03 F7 To program the R8 to respond to Start Stop and Continue messages send it the following System Exclusive programming command is optional All bytes must be in Hexadecimal format see hexadecimal conversion table at end Relay 00 for Relay1 07 for Relay8 is set as follows if is omitted then 00 relay CLOSES for Start Continue OPENS for Stop 01 relay OPENS for Start Continue CLO...

Page 8: ...y is optional where is the System Exclusive message the relay is being programmed to respond to All bytes must be in Hexadecimal format see hexadecimal conversion table at end Relay 00 for Relay1 07 for Relay8 Pulse width OPEN pulse in 8 ms increments or 1 s increments if preceded by 00 To program the R8 to CLOSE Relay8 when the MIDI Machine Control command F0 7F 7F 06 02 F7 is received and OPEN i...

Page 9: ...decimal 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 13 14 1F 20 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4F 50 53 54 55 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 77 78 7F Control Function Bank Select Modulation wheel or lever Breath Controller Undefined Foot controller Portamento time Data entry MSB Channel Volume Balance Undefined Pan Expression Controller Effect Controls 1 2 Undefined General ...

Page 10: ...r no circumstances will MIDI Solutions be liable for any loss of profits benefits time interrupted operation commercial loss or consequential damages arising out of the use or inability to use the product MIDI Solutions specifically disclaims any implied warranties of merchantability and fitness for a particular purpose If the product requires service a Return Merchandise Authorization RMA number ...