4 Screw
For fixing the reinforced panel
Side view of fan assembly
installation state
Front view of fan assembly installation state
Fan assembly should
push horizontally to the
end (about 18mm), and
then take o f f it.
The state after fan assembly is taken off
Fig.4-13
Fig.4-14
Inside of structure
FIiler
Motor Asseembly
Safety Drain Tray
11-Screw
For fixing the satety drain tray
Fortified panel
Move 18mm
Move
Scroll
Pothook
4 Bolts
For fixing the fan assembly
CA U TION
1. Refer to Fig.4- 1 3, remove all 1 1 bolts from safety drain tra y , and take o f f the safety drain tra y .
2. Refer to Fig.4- 1 3, remove all 4 bolts from reinforced panel, and take o f f the panel.
3. Refer to Fig.4-13, remove all 4 bolts from fan assembly, see Fig.4-14, accor ding to which orders to take off the fan assembly.
4. Refer to Fig.4-14, horizontal pushing the fan assembl y , until it cannot not move any furthe r , and then lift up slightly and take down to remove it.
5. After motor maintenance, reinstall the fan assemblies as per the reverse above orders. And connect the motor with electric control box,
as motor with power cable of capacit y .
1. Please shut down the unit and cut o f f power cabl e before maintain the moto r .
2. Before dismount the fan assembl y , you must remove the motor and electric control box, as well a s connective wires between
motor and capacity assembl y .
3. Fan subassembly is very heav y , please be carefu l during maintaining, otherwise physical injury would be caused.
maintenance of motor
maintenance of motor
:
:
6