![Midea SMK-60/CGN8 Service Manual Download Page 26](http://html1.mh-extra.com/html/midea/smk-60-cgn8/smk-60-cgn8_service-manual_1790606026.webp)
M‐Thermal Split
201909 25
P
art 3 ‐
Con
tr
ol
6.6
Smart grid control
Unit adjusts the operation according to different electrical signals to realize energy saving.
Free electric energy signal: DHW mode turn on, the setting temperature will be changed to 70
℃
automatically, and the
TBH operate as below:T5<69. the TBH is on, T5
≥
70, the TBH is off. The unit operate in cooling/heating mode as the
normal logic.
Common electric energy signal: unit operates according to users’ need.
Expensive electric energy signal: only available for cooling or heating mode and user can set the maximum operating time.
Midea CAC Confidential