background image

9

Specifications  subject to change without notice.

DEFAULT VALUES OF INDOOR UNITS

Table 2—Default Values of Indoor Units

Description

Remote Code

Cassette

Ducted

Console

Auto-Start Function

F1

ON

ON

ON

Heating Temperature Compensation

F2

6C

6C

0C

Anti-Cold Air Function

F3

NORMAL

NORMAL

NORMAL

Indoor Fan Motor Speed Control after Set Temperature is Reached

F4

SET SPEED

SET SPEED

SET SPEED

Louver Angle Memory Function

F5

N/A

N/A

N/A

Heating Only or Cooling and Heating Setting

F6

CH

CH

CH

Cooling Temperature Compensation

F7

-2C

-2C

-2C

Refrigerant Leakage Detection

F8

ON

ON

ON

Cleaning Filter Reminder

F9

OFF

OFF

OFF

Filter Replacement Reminder

E1

OFF

OFF

OFF

Lowest Temperature Setting

E2

17C

17C

17C

Highest Temperature Setting

E3

30C

30C

30C

Special Anti-Cold Air Function Setting

E4

N/A

N/A

N/A

Priority Setting of Heating or Cooling (Multi-Zone Systems only)

E5

H

H

H

Network Address Setting

E6

N/A

N/A

N/A

Capacity Code Selection

E7

N/A

N/A

N/A

Twins Setting

E8

N/A

N/A

N/A

Static Pressure Setting

E9

N/A

0

N/A

POINT CHECK FUNCTION

Press  LED 

 on the remote controller three times and then press SWING 

  three times within 10 seconds, the buzzer rings for 2 seconds and the air

conditioner enters the information enquiry status. Next, press LED 

 to search the information. Press SWING 

 to search the remaining information.

When the air conditioner enters the enquiry information status, it displays the code name in 2 seconds (see Table 3).

Table 3—Information Codes

Enquiry Information

Displaying Code

Meaning

T1

T1

Return temperature

T2

T2

Indoor Coil temperature

T3

T3

Outdoor Coil temperature

T4

T4

Outdoor Air temperature

T2B

Tb

Indoor Coil Leaving temperature

TP

TP

Compressor Discharge temperature

TH

TH

IPM Heatsink temperature

Targeted Frequency

FT

Targeted Frequency

Actual Frequency

Fr

Actual Frequency

Indoor fan speed

IF

Indoor fan speed

Outdoor fan speed

OF

Outdoor fan speed

EXV opening angle

LA

EXV opening angle

Compressor continuous running time

CT

Compressor continuous running time

Causes of compressor stop

ST

Causes of compressor stop

Reserve

A0

Reserve

A1

Reserve

.b0

Reserve

.b1

Reserve

.b2

Reserve

.b3

Reserve

.b4

Reserve

.b5

Reserve

.b6

Reserve

.dL

Reserve

Ac

Reserve

Uo

Reserve

Td

Summary of Contents for RG58D/BGEFU1

Page 1: ...g F6 7 Cooling Temperature Compensation F7 7 Refrigerant Leakage Detection F8 7 Cleaning Filter Reminder F9 7 Filter Replacement Reminder E1 7 Lowest Temperature Setting E2 8 Highest Temperature Setti...

Page 2: ...f other electrical appliances respond to the remote controller either move the appliances or consult your local dealer CAUTION Replacing Batteries The remote controller uses two alkaline dry batteries...

Page 3: ...ng hours DOWN Use to decrease the set temperature or Timer setting hours 3 FAN Use to select fan speeds HIGH MED LOW AUTO 4 FAN Use to select fan steps AUTO LOW MED HIGH 5 SWING Use to start or stop h...

Page 4: ...Pressing SET MODIFY only displays the default value for that setting 7 To change the parameter use the TEMP or until the value you want appears 8 Press FAN to confirm the new setting value and transmi...

Page 5: ...on in Celsius regardless of the units used 1 Press and to select F2 Fig 14 Select F2 2 Press MODIFY Next press and to select the parameter The parameters can be adjusted within a range of 21 2_F 42 8_...

Page 6: ...t 2 3 Press MODIFY to adjust the parameter in the range of 46_F 8_C 82_F 28_C Fig 23 Adjust the parameter 4 Press FAN to CONFIRM Fig 24 FAN Indoor Fan Motor Speed Control after Set Temperature is Reac...

Page 7: ...lsius only NOTE Temperature compensation in Celsius regardless of the units used 1 Press and to select F7 Fig 34 Select F7 2 Press MODIFY Next press and to select the parameter range 2_C 2_C 3 Press F...

Page 8: ...g or Cooling only on Multi Zone Systems E5 All heads must be set to the same priority CAUTION 1 Press and to select E5 Fig 47 Select E5 2 Press MODIFY Next press and to select H or C 3 Press FAN to CO...

Page 9: ...etting E9 N A 0 N A POINT CHECK FUNCTION Press LED on the remote controller three times and then press SWING three times within 10 seconds the buzzer rings for 2 seconds and the air conditioner enters...

Page 10: ...131 139 E0 E1 E9 140 141 149 F0 F1 F9 150 151 159 Indoor fan speed Outdoor fan speed 0 OFF 1 2 3 4 Low speed Medium speed High speed Turbo For some big capacity motors 14 FF Actual fan speed Display v...

Reviews: