SAFETY PRECAUTIONS

CAUTION

When the air filter is to be 
removed, do not touch the 
metal parts of the unit.

It may cause an injury.

Do not clean unit when 
power is on as it may cause 
fire and electric shock, it may
cause an injury.

Operation with windows 
opened may cause wetting
of indoor and soaking of 
household furniture.

When the unit is to be 
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close 
the window in storm or 
hurricane.

Use caution when unpacking 
and installing. Sharp edges 
could cause injury.

Do not clean the air 
conditioner with water.

Water may enter the unit and 
degrade the insulation. It may 
cause an electric shock.

This could injure the pet or
plant.

Do not put a pet or house 
plant where it will be
exposed to direct air flow.

Ventilate the room well 
when used together 
with a stove, etc.

An oxygen shortage 
may occur.

Do not use this air cond-

itioner to preserve preci-

sion devices, food, pets, 

plants, and art objects.

It may cause deterioration 

of quality, etc. 

It may cause failure of 

product or fire.

Do not use for 
special purposes.

Turn off the main power  
switch when not using 
the unit for a long time.

If water enters the 
unit, turn the unit off 
and disconnect the 
power , contact a  
qualified service 
technician.

!!

! !

! !

! !

! !

! !

! !

It may cause failure of 
appliance or accident.

Appearance may be 
deteriorated due to change
of product color or 
scratching of its surface.

Do not place obstacles 
around air-inlets or inside 
of air-outlet.

Do not use strong detergent
such as wax or thinner. Use 
a soft cloth for cleaning.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or 
electric shock.

Ensure that the installation bracket of 
the outdoor appliance is not damaged 
due to prolonged exposure.

Do not place heavy object on the 
power cord and take care so that
the cord is not  compressed.

Operation without filters 

may cause failure.

Always insert the filters 
securely. Clean filter 
once every two weeks.

! !

! !

! !

Summary of Contents for MSX HRDN1 Series

Page 1: ...it for future reference Before using your air conditioner please read this manual carefully and keep it for future reference Before using your air conditioner please read this manual carefully and ke...

Page 2: ...rd is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Page 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Page 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Page 5: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Page 6: ...l louver 7 Vertical louver 8 Air filter 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 Power cord 15 Connecting cable 16 Connective pipe 1...

Page 7: ...n function is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit SE...

Page 8: ...is used for testing purposes only To restore the remote controller operation use the remote controller directly CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 I...

Page 9: ...horizontal louver will swing up and down automatically To stop the function press the DIRECTION SWING button again The DIRECTION SWING button will be disabled when the air conditioner is not in operat...

Page 10: ...perature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cool...

Page 11: ...system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter...

Page 12: ...to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the Air Freshening Filt...

Page 13: ...igh relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air condi...

Page 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Page 15: ...Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Rep...

Page 16: ...CS436 U...