Service manual
- 31 -
Manual operation is controlled by touching buttons and divided into force cooling and forced auto
mode. It transfer between these two modes by pressing the buttons, the cycling order of the button
press is as below graph show to you.
10.12 Sleep mode
10.12.1
The sleep function is available at cooling, heating or auto mode
10.12.2 Cooling:
The set temperature rise 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the fan speed is kept at low speed.
10.12.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
10.12.4 Auto:
After an hour running under economic mode, the set temp will rise 1
℃
,if it is under cooling mode; the
set temp will decrease 1
℃
,if it is under heating mode; the set temp will be changeless, if it is under
fan-only mode; the condition will be the same after the air conditioner running under economic mode
after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7
hours the unit stops.
10.13 Auto restart function
Summary of Contents for MSG-24CRN2
Page 1: ...MSG 24CRN2 MSG 24HRN2 MSG 30CRN2 MSG 30HRN2...
Page 2: ......
Page 13: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Page 15: ...Service manual 11 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Page 16: ...Service manual 12 7 2 Wiring diagram 7 2 1 Cooling mode MSG 24CR MSG 30CR...
Page 17: ...Service manual 13 7 2 2 Heating mode MSG 24HR MSG 30HR A1 A2...
Page 18: ...Service manual 14 7 2 3 Cooling mode 3 Ph MSG 30CR 3ph...
Page 19: ...Service manual 15 7 2 4 Heating mode 3 Ph MSG 30HR 3ph 1 7 3 4 5 6 2...