Service manual
- 8 -
MSE-12CRN1-BQ8W
MSE-12HRN1-BQ8W
Ph-V-Hz
1, 115V~,60Hz
1, 115V~,60Hz
Capacity
Btu/h
12000
12000
Input
W
1090
1090
Rated current
A
10
10
SEER
Btu/w.h
13
13
Capacity
Btu/h
/
12500
Input
W
/
1060
Rated current
A
/
10
COP
W/W
/
7.7
A
17.2
17.2
A
47
47
Model
EA108X1C-1FZDU1
EA108X1C-1FZDU1
Type
ROTARY
ROTARY
Brand
TOSHIBA
TOSHIBA
Capacity
Btu/h
10918
10918
Input
W
1085
1085
Rated current(RLA)
A
9.9
9.9
Locked rotor Amp(LRA)
A
47
47
Thermal protector
B440-135-141E
B440-135-141E
Capacitor
uF
45
µ
F /250VAC
45
µ
F /250VAC
Refrigerant oil
ml
350
350
Model
WZDK25-38D
WZDK25-38D
Brand
WELLING
WELLING
Input
W
32
32
Capacitor
uF
——
——
Speed(hi/mi/lo)
r/min
1270/1100/1000
1270/1100/1000
m3/h
800/730/600
800/730/600
dB(A)
44/40/36
44/40/36
Model
YDK23-6A
YDK23-6A
Brand
BROAD OCEAN
BROAD OCEAN
Input
W
75
75
Capacitor
uF
6.5uF/260V
6.5uF/260V
Speed
r/min
900
900
m
3
/h
1850
1850
dB(A)
56
56
g
1330
1350
MPa
4.5
4.5
Liquid side/ Gas side
mm
Ф
6.35/
Ф
12.7
Ф
6.35/
Ф
12.7
Max. refrigerant pipe length
m
10
10
Max. difference in level
m
5
5
℃
17-30
17-30
℃
18-45
-7-45
m
2
18-26
18-26
Model
Power supply
Cooling
Heating
Max. current
Starting current
Compressor
Indoor
fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.