PROBLEM POSSIBLE
CAUSE REMEDY
No power display
on panel or any
one of the buttons
failure.
Power failure
Check the power supplier if the power supplier is supplied
to the unit. Check the power cord and correct if damaged.
Transformer (Discharge
transformer before
testing)
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the
input/output is open or the transformer is damaged.
Display board or main
PCB failure
Check the voltage on display board. Replace the display
board if it is +5V else replace the main PCB.
Remote control
failure.
Battery failure
Check the voltage of battery. Replace batteries if the
voltage is lower than 2.3V.
Fan motor runs
intermittently
Cycles on overload.
Check voltage. Call an electrician if not within limits.
Test capacitor.
Replace if not /-10% of manufacture's rating.
Check bearings. Replace the motor if the blower wheel
cannot rotate freely.
Pay attention to any change from high speed to low speed.
Replace the motor if the speed does not change.
Compressor
stops instantly
after startup.
Refrigerant
The amount of the refrigerant is too much, making the
compressor load too big. Recycle and recharge the
refrigerant after checking for the reason.
Compressor
The compressor is blocked inside. Replace after checking
for the reason.
Fan motor will not
run.
No power
Check voltage at electrical outlet. Correct if none.
Water alarm
Check and correct if water alarm happens.
Power supply cord
Check voltage at the power cord terminal on Main PCB.
Replace the power cord if none.
Transformer (Discharge
transformer before
testing)
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the
input/output is open or the transformer is damaged.
Wire disconnected or
connection loose
Connect wire. Refer to wiring diagram for terminal
identification. Repair or replace loose terminal.
Main PCB failure
Select fan speed and Check the voltage on main PCB.
Replace the main PCB if no voltage in anyone.
Capacitor (Discharge
capacitor before testing)
Test capacitor.
Replace if not /-10% of manufacture's rating.
Replace if shorted, open or damaged.
Will not rotate
Fan blower hitting scroll. Realign assembly.
Check fan motor bearings. Replace the motor if motor shaft
do not rotate.
Fan motor noise.
Fan blower
Replace the fan blower if cracked, out of balance, or
partially missing.
Summary of Contents for MPM1-10CEN1-BB6
Page 1: ...Portable air conditioner MPM1 10CEN1 BB6 MPM1 10EEN1 BB6 MPM1 10CRN1 BB6 MPM1 10ERN1 BB6...
Page 7: ...Outer dimension 5 3 Out dimension...
Page 8: ...External view part display 6 4 Display 4 1 LED display 4 2 LCD display...
Page 15: ...Installation detail 13 6 6 4 Cover the hole using the adaptor cap when not in use...
Page 32: ...Exploded view spare part 30 12 Exploded view spare part 12 1 Exploded view of unit...
Page 33: ...Exploded view spare part 31 12 2 Exploded view of accessory part...