Page 11
Outdoor Unit Installation
5
Outdoor Unit Installation Instructions
Step 1: Select installation location.
The outdoor unit should be installed in the location that
meets the following requirements:
Place the outdoor unit as close to the indoor unit as
possible.
Ensure that there is enough room for installation and
maintenance.
The air inlet and outlet must not be obstructed or
exposed to strong wind.
Ensure the location of the unit will not be subject to
snowdrifts, accumulation of leaves or other seasonal
debris. If possible, provide an awning for the unit.
Ensure the awning does not obstruct airflow.
The installation area must be dry and well ventilated.
There must be enough room to install the connecting
pipes and cables and to access them for maintenance.
The pipe length between the outdoor and indoor unit
may not exceed the maximum allowable pipe length.
Strong wind
Strong wind
Strong wind
Fig.
5.1
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
Fix with bolts
CAUTION
•
Be sure to remove any obstacles that
may block air circulation.
•
Make sure you refer to Length
Specifications to ensure there is
enough room for installation and
maintenance.
Fig. 5.3
Outdoor Unit
Installation
>60cm
Fig.
5.2
If the location is exposed to strong winds the unit
must be placed against the wall to shelter it from
the wind.
Summary of Contents for MOB01-09HFN8-QRD6GW
Page 1: ...Installation Manual Mission Series R410a Models R32 Models...
Page 6: ...Page 6 Installation Overview 3 Unit Installation Overview INSTALLATION ORDER...
Page 8: ...Page 8 Indoor Unit Installation 4...
Page 10: ...Page 10 Indoor Unit Installation 4...
Page 14: ...For MOCA02 24HFN1 QRD0GW Page 14 Outdoor Unit Installation Instructions...
Page 16: ...Drainpipe Installation 6 Page 16...
Page 39: ...17 Old Park Lane London W1K 1QT Tel 44 0 2074 092009...