Oasis On-off
DM12-01.01.09en
38
Service
manual
10.4 Operation Modes and Functions
10.4.1 Fan mode
(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates the same as in cooling mode.
(5) Auto fan:
29
28
High
Low
25
Medium
10.4.2 Cooling Mode
10.4.2.1 Compressor running rules
Once the compressor starts up, it will run 5.5 minutes. And then it will follow the below rules:
When indoor room temp.T1 is lower than Tn, the compressor and outdoor fan will shut off. When T1 is
higher than Tm, the compressor and outdoor fan will start up.
Tm=Ts, Tn=Ts-2.