10

installation & owner’s manual

Arrange the drain hose to ensure smooth drainage.

Incomplete  drainage  may  cause  wetting  of  the  building, 
furniture etc.

Never touch the internal parts of the controller.

 

Do  not  remove  the  front  panel.  Some  parts  inside  are 
dangerous to touch, and a machine trouble may happen.

Never expose little children, plants or animals directly to 
the air flow. 

Adverse  influence  to  little  children,  animals  and  plants  may 
result.

Do  not  allow  a  child  to  mount  on  the  outdoor  unit  or 
avoid placing any object on it.

 

Falling or tumbling may result in injury.

Do  not  operate  the  air  conditioner  when  using  a  room 
fumigation - type insecticide. 

Failure  to  observe  could  cause  the  chemicals  to  become 
deposited  in  the  unit,  which  could  endanger  the  health  of 
those who are hypersensitive to chemicals.

Do  not  place  appliances  which  produce  open  fire  in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It may cause incomplete combuston or deformation of the unit 
due to the heat.

Do  not  install  the  air  conditioner  at  any  place  where 
flammable gas may leak out. 

If the gas leaks out and stays around the air conditioner, a fire 
may break out. 

The appliance is not intended for use by young children 
or infirm persons without supervision.
 
Young children should be supervised to ensure that they 
do not play with the appliance

.

2.    PARTS NAMES

The air conditioner consists of the indoor unit, the outdoor unit, 
the connecting pipe and the remote controller.

(Refer to Fig.1)

Function indicators on indoor unit display panel

PRE-DEF indicator(cooling and heating
 type) 
or fan only indicator(cooling only type)

Infrared signal receiver

Operation lamp

Timer indicator

Temporary button

This  manual  does  not  include  Remote  Controller 
Operations,  see  the<<Remote  Controller  Owner's 
manual>> packed with the unit for details. 

AUTO
The  OPERATION  lamp  is  lit,  and  the  air  conditioner  will  run 
under AUTO mode. The remote controller operation is enabled 
to operate according to the received signal.

FORCED COOL
The air conditioner will turn to AUTO after it is enforced to cool 
with a wind speed of LOW for 30 minutes. The remote controller 
operation is disabled.
 
COOLING TEST
Partial units have this function.
The function just be used during test and maintenance.

HEATING TEST
Partial units have this function.
The function just be used during test and maintenance.

OFF
The  OPERATION  lamp  goes  off.  The  air  conditioner  is  OFF 
while the remote controller operation is enabled.

1

2

3

4

5

Display panel

Fig. 2-1

This function is used to operate the unit temporarily in case you 
misplace  the  remote  controller  or  its  batteries  are  exhausted. 
Two  modes  including  AUTO  and  FORCED  COOL  can  be 
selected  through  the  TEMPORARY  BUTTON  on  the  display 
panel. Once you push this button, the air conditioner will run in 
such  order:  AUTO,  FORCED  COOL,(COOLING  TEST 
HEATING TEST,)OFF, and back to AUTO.

NOTE

Use the system in the following temperature for safe and
effective  operation.The  Max  operation  temperature  for 
the air conditioner.(Cooling/Heating)

3.    AIR CONDITIONER OPERATIONS AND     

       PERFORMANCE

Cooling operation

Dry operation

Heating operating
(cooling only 

type without)

Temperature

Outdoor
temperature

Room
temperature

21         43

-5         24

0        30

17         32

11         43

17         30

Table 3-1

1

If air conditioner is used outside the above conditions, it may 
cause the unit to function abnormally.

Room  relative  humidity  should  be  less  than  80%.  If  the  air 
conditioner is over it , the surface of the air conditioner may 
condense water . Please set the vertical air flow louver to its 
maximum angle (vertically to the floor), and set HIGH speed.

Optimum  performance  will  be  achieved  within  these 
operating temperature range. 

2

3

Three-minute protection feature

A  protection  feature  prevents  the  air  conditioner  from  being 
activated  for  approximately  3  minutes  when  it  restarts 
immediately after operation.

CAUTION

Summary of Contents for MFA-12HRDN1-Q

Page 1: ...ding Type OWNER S MANUAL REMOTE CONTROLLER INSTALLATION Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Page 2: ...ote controller All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE Air flow louver at air outlet Air inlet with air filter in it INDOOR UNIT OUTDOOR UNIT 1 6 7 1 3 4 2 5 7 8 9 Water tray Fig 1 ...

Page 3: ... service the equipment Improper installation repair and maintenance may result in electric shocks short circuit leaks fire or other damage to the equipment Install according to this installation instructions strictly If installation is defective it will cause water leakage electrical shock fire When installing the unit in a small room take measures against to keep refrigerant concentration from ex...

Page 4: ... part of the building it must be electrically insulated according to the relevant standards to electrical appliances When all the installation work is finished please turn on the power only after a thorough check Regret for no further announcement if there is any change of this manual caused by product improvement 2 INSTALLATION INFORMATION Ground the air conditioner Do not connect the ground wire...

Page 5: ...thers 4 Mounting screw ST2 9 10 C H Fig 3 1 Never throw or beat the controller Before installation operate the remote controller to determine its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or noise interferences Do not install the remote controller in a place exposed to direct ...

Page 6: ... prevent image interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 meter is kept There is enough room for installation and maintenance Refer to Fig 5 1 and Fig 5 2 The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room...

Page 7: ... Refer to Fig 6 1 If possible do not install the unit where it is exposed to direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the drain hole to an appropriate place so as not to interfere other people Select the position where it will not be subject to ...

Page 8: ...eful when lifting it with a sling Never hold the inlet of the outdoor unit to prevent it from deforming Do not touch the fan with hands or other objects Do not lean it more than 45 and do not lay it sidelong Make concrete foundation accoding to the sepecif ications of the outdoor units Refer to Fig 6 6 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthqua...

Page 9: ...e any winding The total length of the drain pipe when pulled out traversely shall not exceed 20m when the pipe is over long a prop stand must be installed to prevent winding Refer to the figures on the right for the installation of the pipes 8 CONNECT THE DRAIN PIPE Install the drainpipe of the indoor unit The outlet has PTI screw bread Please use sealing materials and pipe sheath fitting when con...

Page 10: ...gram located on the panel of the outdoor unit to connect the wire The connection cables of indoor and outdoor units have been connected to the terminals on the control board Remove the control cover from the outdoor unit by loosening the screw Hold the indoor plug connector and insert the mating plug connector located on the outdoor unit until it fixed with a clicking sound Secure the cable onto t...

Page 11: ...order to avoid electric shock make sure that the unit is grounded and that the earth wire is not connected to gas or water pipe lightning conductor or telephone earth wire In order to avoid injury do not remove the fan guard of the outdoor unit Do not operate the air conditioner with a wet hand An electric shock may happen Do not touch the heat exchanger fins These fins are sharp and could result ...

Page 12: ...ils AUTO The OPERATION lamp is lit and the air conditioner will run under AUTO mode The remote controller operation is enabled to operate according to the received signal FORCED COOL The air conditioner will turn to AUTO after it is enforced to cool with a wind speed of LOW for 30 minutes The remote controller operation is disabled COOLING TEST Partial units have this function The function just be...

Page 13: ...low direction properly to avoid winding toward your body Adjust the room temperature properly to get a comfortable situation and to avoid supercooling and superheat In cooling close the curtains to avoid direct sunlight To keep cool or warm air in the room never open doors or windows more often than necessary Set the timer for the desired operating time Never put obstructions near the air outlet o...

Page 14: ...the operating mode or situation air blows from the upper air outlet Use this switch when you do not want air coming out of the lower air outlet While sleeping stc Operating mode Situation Blowing pattern COOL mode HEAT mode When the room has become fully cool or when one hour has passed since turning on the air condition er So that air does not come into dir ect contact with people air is blo wn u...

Page 15: ...uum cleaner Refer to Fig 7 4 The air in side should face down when using water Refer to Fig 7 5 Press the claws on the right and left of the air filter down slig htly then pull upward Refer to Fig 7 2 Take off the especial function filter 3 Hold the tabs of the frame and remove the claws in 4 places Refer to Fig 7 3 The especial function filter can be renewed by washing it with water once every 6 ...

Page 16: ...inuous low shah sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing soun...

Page 17: ...unlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrige rant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the con troller Set the temperature properly Wait Check leakage and rightly recharge ref rigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Find r...

Page 18: ...e ON OFF button is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears ...

Page 19: ... ON to 0 00 ECONOMIC RUNNING Button Press this button to go into the Energy Saving operation mode Press the button again to cancel TIMER OFF Button Press this button to preset the time OFF turn off the operation Each press will increase the time OFF setting in 30 minutes increments When the setting time displays 10 00 each press will increase the time OFF setting in 60 minutes increments To cancel...

Page 20: ...seconds the signal h disappears and the set temperature will re appear on the digital display 1 2 3 The Remote Controller uses two alkaline dry batteries LR03X2 Use the MODE select button to select AUTO Push the TEMP button to set the desired room temperature The most comfortable temperature setting are between 21 ć to 28ć Push the ON OFF button to start the air conditioner The OPERATION lamp on t...

Page 21: ...er and the receiver of indoor unit otherwise the air conditioner will not work Keep the Remote Controller away from any liquids Protect the remote controller from the high temperatures and exposure to radiation Keep the indoor receiver out of direct sunlight or the Air Conditioner may malfunction Keep Remote Controller away from EMI Electro Magnetic Interference supplied by other household applian...

Page 22: ...QSZIU 001AEN 202000100543 ...

Reviews: