Control pads

3

3

When you push the button to change
operation modes, the unit will make 
a beep sound to indicate that it is 
changing modes.

NOTE:

 The control panel of the unit you purchased may be slightly different according 

to the models. 

Fig.1

2

2

Humidity Set Control Pads

: Up/Down Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto start and 
Auto stop time from 0.0 to 24.

The humidity level can be set within a range of 
35%RH(Relative Humidity) to 85%RH(Relative 
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower 
percent value(%). 
For damper air, press the      pad and set  a higher 
percent value(%).

CONTROL PADS ON THE DEHUMIDIFIER

5

5

Timer Pad

Press to initiate the Auto start and Auto stop 
feature, in conjuction with the       and        pads.

1

1

4

4

Power Pad

Press to turn the dehumidifier on and off.

1

1

2

2

3

3

4

4

5

5

6

6

7

7

Unit operation on
indicator light

8

8

Fan speed 
indicator light

Wireless operation 
on indicator light

Bucket full 
indicator light

Continuous
operation on
indicator light

Dryer operation 
on indicator light

Smart dehumidifying
operation on indicator 
light

Mode Pad

Press to select the desired operation mode from
Dehumidifying,Dryer,Continuous dehumidifying and
Smart dehumidifying. 
NOTE: Dryer and Smart dehumidifying modes are
optional.

 

6

6

Fan Pad

7

7

Wireless Pad(optional)

Press this pad for 3 seconds to initiate the 
Wireless connection mode. The LED DISPLAY 
shows 'AP' (at this time the unit shuts off all other 
functions) to indicate you can set Wireless 
connection. If connection(router) is successful 
within 8 minutes, the unit will exit Wireless 
connection mode automatically and the Wireless
 indicator illuminates and the unit enters the 
previous functions. If connection is failure within 
8 minutes, the unit exits the Wireless connection 
mode automatically.

Control the fan speed. Press to select 
fan speed in three steps-low, med and 
high. The fan speed indicator light 
illuminates under different fan speed 
settings. But when select high fan speed, 
both the low and med fan speed lights 
illuminate.

NOTE: When the compressor startups or stops
running, the unit may make a loud voice, it is normal.

Timer 
indicator light

 

the equipment are removed from site promptly and all isolation valves on the equipment are 

closed off. 

k) Recovered refrigerant shall not be charged into another refrigeration system unless it has 

been cleaned and checked.

15.Labelling

Equipment shall be labelled stating that it has been de-commissioned and emptied of 

refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment 

stating the equipment contains flammable refrigerant.

16.Recovery

When removing refrigerant from a system, either for servicing or decommissioning, it is 

recommended good practice that all refrigerants are removed safely. 

When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery 

cylinders are employed. Ensure that the correct number of cylinders for holding the total system 

charge is available. All cylinders to be used are designated for the recovered refrigerant and 

labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall 

be complete with pressure relief valve and associated shut-off valves in good working order. 

Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. 

The recovery equipment shall be in good working order with a set of instructions concerning 

the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. 

In addition, a set of calibrated weighing scales shall be available and in good working order. 

Hoses shall be complete with leak-free disconnect couplings and in good condition. Before 

using the recovery machine, check that it is in satisfactory working order, has been properly 

maintained and that any associated electrical components are sealed to prevent ignition in the 

event of a refrigerant release. Consult manufacturer if in doubt.

The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery 

cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery 

units and especially not in cylinders. If compressors or compressor oils are to be removed, 

ensure that they have been evacuated to an acceptable level to make certain that flammable 

refrigerant does not remain within the lubricant. The evacuation process shall be carried out 

prior to returning the compressor to the suppliers. Only electric heating to the compressor 

body shall be employed to accelerate this process. When oil is drained from a system, it shall 

be carried out safely.

SAFETY PRECAUTIONS

Summary of Contents for MDDF-16DEN7-QA3

Page 1: ... product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version GD MIDEA AIR CONDITIONING EQUIPMENT CO LTD Lingang Road Beijiao Shunde Foshan Guangdong People s Republic of China 528311 MODEL MDDF 16DEN7 QA3 REFRIGERANT R290 0 075kg MODEL MDDF 20DEN7 QA3 REFRIGERANT R290 0 075kg ...

Page 2: ...sed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when ...

Page 3: ...or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemicals and solvents dissolved in the air Care should be taken when using the unit in a room with the following persons Infants children elderly people and people not sensitive to humidity You may be inj...

Page 4: ...burn Be aware that the refrigerants may not contain an odour C Appliance should be installed operated and stored in a room with a floor area 2 larger than 4 m ompliance with national gas regulations shall be observed Keep ventilation openings clear of obstruction The appliance shall be stored so as to prevent mechanical damage from occurring A warning that the appliance shall be stored in a well v...

Page 5: ...fected This shall include damage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted securely Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of 1 Transport of equipment containing flammable refrigerants See transport regulations 2 ...

Page 6: ...aximum working pressure of the cylinder even temporarily j When the cylinders have been filled correctly and the process completed make sure that the cylinders and preventing the ingress of flammable atmospheres Replacement parts shall be in accordance with the manufacturer s specifications NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intr...

Page 7: ...lves on the equipment are closed off k Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked 15 Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 1...

Page 8: ...m humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Codes AS Humidity sensor module error Unplug the unit and plug it back in If error repeats call for service Auto Shut Off The dehumidifier shuts off when the bucket is full or when the bucket is removed or not replaced in the proper position For some models the fan motor will continue opera...

Page 9: ...ustrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bucket of water Allow at least 20cm of air space on all sides of the unit for good air circulation Place the unit in an area where the temperature will not O O fall below 5 C 41 F The coils can become covered with O O frost at temperatures below 5 C 41 F which may reduce performance Pl...

Page 10: ...sily so use a vacuum attachment or brush to clean 2 Clean the bucket Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket empty and rinse NOTE Do not use a dishwasher to clean the bucket After clean the bucket must be in place and securely seated for the dehumidifier t...

Page 11: ...or surface is not level Frost appears on the coils This is normal The dehumidifier has Auto defrost feature Water on floor Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed ES AS or P2 appear in the display These are error codes and protection codes See the CONTROL PADS ON THE DEHUMIDIFIER section 19 19 NOTE The cabinet a...

Reviews: