![Midea MCHS-09PSH1 Service Manual Download Page 19](http://html1.mh-extra.com/html/midea/mchs-09psh1/mchs-09psh1_service-manual_1790756019.webp)
7. Operation Characteristics
CAUTION:
1. If the air conditioner is used beyond the above conditions, certain safety protection features
may come into operation and cause the unit to operate abnormally.
2. The room relative humidity should be less than 80%. If the air conditioner operates beyond this
figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow
louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. The optimum performance will be achieved during this operating temperature zone.
9k(115V) 12k(115V) 9k(230V) 12k(230V)
18k
24k
30k
36k
O
pe
rati
n
g Ra
nge
Cooling
Outdoor
Min - Max
DB
°F (°C)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
4-122
(-20-50)
Indoor Min
- Max DB
°F (°C)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
63-86
(17-30)
Indoor Min
- Max WB
°F (°C)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
59-84
(15-29)
Heating
Outdoor
DB Min –
Max
°F
(°C)
4-86
(-20-30)
4-86
(-20-30)
(-22)-86
(-30-30)
(-22)-86
(-30-30)
(-22)-86
(-30-30)
(-22)-86
(-30-30)
4-86
(-20-30)
4-86
(-20-30)
Outdoor
WB Min –
Max
°F
(-4)-77
(-4)-77
(-4)-77
(-4)-77
(-4)-77
(-4)-77
(-4)-77
(-4)-77
(°C)
(-20-25)
(-20-25)
(-20-25)
(-20-25)
(-20-25)
(-20-25)
(-20-25)
(-20-25)
Indoor DB
Min –Max
°F
(°C)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
32-86
(0-30)
Summary of Contents for MCHS-09PSH1
Page 1: ...Mission 3D Inverter Series Service Manual 2016 MBSUL A 1604...
Page 8: ...For 9k 12k For 18k 24k For 30k 36k...
Page 11: ...5 Wiring Diagram 5 1 Indoor Unit MEHS 09PSH1 MEHS 12PSH1 MEHSU 09PHH2 MEHSU 12PHH2...
Page 12: ...MEHSU 18PHH2 MEHSU 24PHH2 MEHS 30PSH2 MEHS 36PSH2...
Page 13: ...5 2 Outdoor Unit MCHS 09PSH1 MCHS 12PSH1 MCHSU 09PHH2 MCHSU 12PHH2 MCHSU 18PHH2...
Page 14: ...MCHSU 24PHH2 MCHS 30PSH2 MCHS 36PSH2...
Page 45: ...P W N U...
Page 46: ...N V N W...
Page 78: ...compressor on bottom plate 4 Lift the compressor from the base pan assembly 3...