39
11
Indoor unit D capacity demand code
12
Indoor unit E capacity demand code
13
Outdoor unit amendatory capacity demand
code
14
The frequency corresponding to the total
indoor units' amendatory capacity demand
15
The frequency after the frequency limit
16
The frequency sending to compressor
control chip
17
Indoor unit A evaporator outlet temperature
(T
2B
A)
If the temperature is lower than -9
℃
, the digital display shows “-
9.” If the temperature is higher than 70
℃
, the digital display
shows “70.” If the indoor unit is not connected, the digital display
shows: “――”
18
Indoor unit B evaporator outlet temperature
(T
2B
B)
19
Indoor unit C evaporator outlet temperature
(T
2B
C)
20
Indoor unit D evaporator outlet temperature
(T
2B
D)
21
Indoor unit E evaporator outlet temperature
(T
2B
E)
22
Indoor unit A room temperature (T
1
A)
If the temperature is lower than 0
℃
, the digital display shows “0.”
If the temperature is higher than 50
℃
, the digital display shows
“50.” If the indoor unit is not connected, the digital display shows:
“――”
23
Indoor unit B room temperature (T
1
B)
24
Indoor unit C room temperature (T
1
C)
25
Indoor unit D room temperature (T
1
D)
26
Indoor unit E room temperature (T
1
E)
27
Indoor unit A evaporator temperature (T
2
A)
If the temperature is lower than -9
℃
, the digital display shows “-
9.” If the temperature is higher than 70
℃
, the digital display
shows “70.” If the indoor unit is not connected, the digital display
shows: “――”
28
Indoor unit B evaporator temperature (T
2
B)
29
Indoor unit C evaporator temperature (T
2
C)
30
Indoor unit D evaporator temperature (T
2
D)
31
Indoor unit E evaporator temperature (T
2
E)
32
Condenser pipe temperature (T3)
33
Outdoor ambient temperature (T4)
34
Compressor discharge temperature (TP)
The display value is between 30–129
℃
. If the temperature is
lower than 30
℃
, the digital display shows “30.” If the temperature
is higher than 99
℃
, the digital display shows single and double
digits. For example, if the digital display shows “0.5", the
compressor discharge temperature is 105
℃
.
35
AD value of current
The display value is a hex number.
For example, the digital display tube shows “Cd”, it means AD
value is 205.
36
AD value of voltage
37
EXV open angle for A indoor unit
Actual data/4.
If the value is higher than 99, the digital display shows single and
double digits.
For example, if the digital display shows “2.0", the EXV open
angle is 120×4=480p.
38
EXV open angle for B indoor unit
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
Bit7
Frequency limit caused by IGBT
radiator
The display
value is a
hexidecimal
number. For
example, the
digital display
show 2A, then
Bit6
Frequency limit caused by PFC
Bit5
Frequency limit caused by T4.
Bit4
Frequency limit caused by T2.
Bit3
Frequency limit caused by T3.
Summary of Contents for MCH2U-18PHH2
Page 3: ...3 MCH4U 36PHH2 WD30 metal plate 118 MCH5U 48PHH2 WE30 metal plate 125...
Page 23: ...23 7 Wiring Diagrams 7 1 Wiring diagram of 1 drive 2 outdoor MCH2U 18PHH2...
Page 24: ...24 7 2 Wiring diagram of 1 drive 3 outdoor MCH3U 27PHH2...
Page 25: ...25 7 3 Wiring diagram of 1 drive 4 outdoor MCH4U 36PHH2...
Page 26: ...26 7 4 Wiring diagram of MCH5U 48PHH2...
Page 31: ...31 PCB board of MCH5U 48PHH2...
Page 32: ...32 IPM board of MCH5U 48PHH2...
Page 44: ...44...
Page 46: ...46 Operating Standby Pic 2 IPM for 2 zone 3 zone...
Page 54: ...54 8 4 1 7 Over voltage or under voltage protection diagnosis and solution...
Page 59: ...59...
Page 61: ...61 Operating Standby Pic 2 IPM board for 2 zone 3 zone...
Page 64: ...64...
Page 68: ...68 IPM board for 2 zone 3 zone...
Page 70: ...70 IPM board for 4 zone...
Page 73: ...73 Two ports of the inductance Inductance...
Page 76: ...76 Vs Vcc Vsp FG...
Page 78: ...78...
Page 79: ...79...
Page 81: ...81...
Page 82: ...82...
Page 84: ...84...
Page 85: ...85...
Page 87: ...87...
Page 98: ...98 6 EXV check Disconnect the connectors...
Page 100: ...100 Red Blue Red Yellow...
Page 101: ...101 Brown Orange...
Page 102: ...102 Brown White...
Page 112: ...112 Screws of front panel Screws of right rear panel Screws of front panel...
Page 120: ...120 Screws of front panel Screws of right rear panel Screws of front panel...