OUTDOOR UNIT INSTALLATION
9
(Refer to chart 17,chart 18)
If possible, please remove the obstacles nearby to prevent the performance from being impeded by too
little of air circulation.
The minimum distance between the outdoor unit and obstacles described in the installation chart does
not mean that the same is applicable to the situation of an airtight room. Leave open two of the three
directions (A,B,C)
CAUTIONS
Keep this unit away from direct radiation of the sun or other heaters.
If unavoidable, please cover it with a shelter.
In places near coast or with a high attitude where the wind is violent, please install the outdoor unit
against the wall to ensure normal performance.
Use a baffle when necessary.
In the case of extremely strong wind, please prevent the air from flowing backwards into the outdoor
unit. ( Refer to chart 16)
Locate the outdoor unit as close to the indoor unit as possible.
The minimum distance between the outdoor unit and obstacles described in the installation chart
does not mean that the same is applicable to the situation of an airtight. Leave open two of three
directions A,B,C..
X
O
Chart 16
S
tr
o
n
g
w
in
d
NECESSARY ROOM FOR INSTALLATION AND MAINTENANCE
>30cm
>60cm
>
30
cm
>
20
0c
m
Chart 17
(Wall or obstacle)
Maintain channel
Air outlet
Air inlet
Air inlet
A
C
B
Chart 18
>
6
0
c
m
Fix with bolt
Necessary width
Deep foundation
Since the gravity center of this unit is not at its physical center, so please be careful when lifting it
with a sling.
Never hold the air-in of the outdoor unit to prevent it from deforming.
Do not touch the fan with hands or other objects.
0
Do not lean it more than 45 , and do not lay it sidelong.
Please fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake
or strong wind.
MOVING AND INSTALLING
Summary of Contents for MCA-24CRN2
Page 22: ...A CS0174N ...