background image

NOTE 

 12 hours preheating is imperative after turn on the power  

switch. Please do not shut down the power when the unit 
is supposed to stop running in 24h or shorter time. (This is  
to warm the crankcase heat box to avoid compulsive start  
of condenser.) 

 Pay attention not to block the air inlet and outlet. 

Blocks may decrease the efficiency of the unit or startup the 
protector, which will stop running. 

3.    OPERATION RANGE

Use the system in the following temperature for safe and 
effective operation. The Max operation temperature for 
the heat pump. (Cooling/Heating) 

Cooling operation 

Heating operating 

Mode 

Temperature 

Outdoor 
temperature 

Water 
temperature 

15

℃~

43

℃ 

  7        22 

℃~   ℃ 

NOTE 

1. 

2. 

3. 

If heat pump is used outside the above conditions, it may 
cause the unit to function abnormally. 

The phenomenon is normal that the surface of indoor unit 
may condense water when the relative larger humidity in 
room, please close the door and window. 

Optimum performance will be achieved within these 
operating temperature range.  

 

15

℃~

55

℃ 

Table 3-1 

-15

℃~

43

℃ 

3

4.    OPERATION AND PERFORMANCE

4.1 Protection Equipment 

  

The protection equipment may be activated in following conditions: 

The air inlet or air outlet of outdoor unit is blocked. 

Strong wind is Continuously blowing to the air outlet of the  

outdoor unit. 

Too much  rubbish adhere to the  filter in the indoor unit 

The air outlet of indoor unit is choked 

Cooling Operation 

Heating Operation 

  

  

  

  

When the protection equipment starts, please shut down the  
manual power switch, and restart operation after problem is 
solved. 

This Protection Equipment will enable the  Heat Pump  to stop 
when the Heat Pump is to be directed running compulsively. 

When the Protection Equipment is activated, the Operation  
Indicator still lights while the Heat Pump is not running. But the Check 
Indicatior Lights.  

NOTE 

4.2 About power cut 

   If power is cut during operation, stop all the operation immediately. 

   Power comes again. The lamp on the display panel of indoor unit  
   flashes. And then unit will auto-restart. 

 Mishandling in operation: 

If mishandling happens because of lighting or mobile wireless,  
please shut off the manual power switch, and turn on again, then 
push the ON/OFF button. 

4.3 Heating capacity 

The heating operation is a heat-pump process that heat will be  
absorbed from outdoor air and released to indoor water. Once 
the outdoor temperature is decreased, heating capacity  
decreased corredpindingly. 
Other heating equipment is suggested to be used together when  
outdoor temperature is too low. 

In some extreme cold upland that buy another inddoor unit  
equipped electrical heater will obtain better performance.(Refer  
to indoor unit owner’s manual for details) 

NOTE 

If the heat pump malfunction occurs because of disturb,  
pleasereconnect the heat pump to power, then turn on it  
again. 

1. 

2. 

owner's manual 

A protection feature prevents the heat pump from being  
activated for approximately 3 minuites when it restarts  
immediately after operation. 

The  the indoor unit in the same system can not run cooling  
and heating at the same time. 

4.6 Features of heating operation 

Water will not become hot immediately at the beginning of  
the heating operation, 3~5 minutes ago (depends on the indoor  
and outdoor temperature), until the indoor heat exchanger  
become hot, then becomes hot. 

During operation, the fan motor in the outdoor unit may stop  
running under high temperature. 

4.7 Defrost in the heating operation 

During heating operation, outdoor unit sometimes will frost. To  
increase efficiency, the unit will start defrosting automatically  
(about 2~10 minutes), and then water will be drained out from 
outdoor unit. 

During defrosting,  the fan motors in the outdoor unit  will  
stop running. 

If  the Heat Pump Administrator has set running mode, then  
the heat pump  can not run on modes other than the presetted. 
Standby or No Priority will be displayed in the Control Panel. 

4.4 Three-minute protection feature 

4.5 Cooling and heating operation 

 

 

The motor in Indoor Unit will continue running for 20~30 
seconds for to remove residual heat when the Indoor 
Unit recoeiving OFFcommand during heating operation. 

Summary of Contents for LRSJF-V N1

Page 1: ...OWNER S MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference DC INVERTER FREE...

Page 2: ...ide air inlet air outlet Fig 1 All the pictures in this manual are for explanation purpose only They may be slightly different from the heat pump you purchased depend on model The actual shape shall p...

Page 3: ...gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the heat pump until a service person confirms that the portion where the...

Page 4: ...in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components shorten their service life spans because of overheated for a long time The...

Page 5: ...el of indoor unit flashes And then unit will auto restart Mishandling in operation If mishandling happens because of lighting or mobile wireless please shut off the manual power switch and turn on aga...

Page 6: ...1 Model E0 E2 E3 E4 E5 P0 P1 P2 P3 P4 P5 P6 P8 P7 EEPROM error Communication error of the outdoor chip and the indoor chip Communication error of 9177and IPDU Communication error of outdoor chip and...

Page 7: ...above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures see in Table 7 1 7 1 Troubles and causes of heat pump 5 owner s manua...

Page 8: ...MDV10U 017CW 202000171551...

Reviews: