water pipe, lightning conductor or telephone earth wire. 
 

In order to avoid injury, do not remove the fan guard of 
the outdoor unit. 

 

Do not operate the heat pump with a wet hand. 

 

An electric shock may happen.  

 
Do not touch the heat exchanger fins. 

 

These fins are sharp and could result in cutting injuries. 
 

Do not place items which might be damaged by moisture 
under the indoor unit. 

 

Condensation may form if the humidity is above 80%, the 
drain outlet is blocked or the filter is polluted.  
 

After a long use, check the unit stand and fitting for 
damage.

  

If damaged, the unit may fall and result in injury. 
 

To avoid oxygen deficiency, ventilate the room 
sufficiently if equipment with burner is used together 
with the heat pump.

 

 

Arrange the drain hose to ensure smooth drainage.

 

Incomplete drainage may cause wetting of the building, 
furniture etc. 
 

Never touch the internal parts of the controller.

  

Do not remove the front panel. Some parts inside are 
dangerous to touch, and a machine trouble may happen. 
 
 

The function of text  run circulate as fowlling.

Never expose little children, plants or animals directly to 
the air flow. 

 

Adverse influence to little children, animals and plants may 
result. 

 
Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

  

Falling or tumbling may result in injury. 

 
Do not operate the heat pump when using a room 
fumigation - type insecticide. 

 

Failure to observe could cause the chemicals to become 
deposited in the unit, which could endanger the health of 
those who are hypersensitive to chemicals. 

 
Do not place appliances which produce open fire in 
places exposed to the air flow from the unit or under the 
indoor unit.

  

It may cause incomplete combuston or deformation of the unit 
due to the heat. 
 

Do not install the heat pump at any place where 
flammable gas may leak out.  

If the gas leaks out and stays around the heat pump, a fire 
may break out.  
 

The appliance is not intended for use by young children 
or infirm persons without supervision. 
  
Young children should be supervised to ensure that they 
do not play with the appliance

 

The outdoor unit window-shades should be periodic 
cleaning in case of being jammed. 

This window-shapes is heat dissipation outlet of components, 
if being jammed will cause the components shorten their 
service life spans because of overheated for a long time. 

 

The temperature of refrigerant circuit will be high, please  
keep the interconnection cable away from the copper 
tube. 

2.    PARTS  NAMES

The heat pump consists of the indoor unit, the outdoor 
unit, the connecting pipe and the remote controller.  
(see Fig.1) 

2

owner's manual 

Force Cooling Control  

 

Display function 

MAIN BOARD 

Force cooling  
control Button sw2 

Display control button sw1 

Force Cooling Control 

Fig.2-2 

(OUTDOOR UNIT)

Fig.2-3 

Force cooling control of outdoor unit be pressed once that a order  
to force cooling in indoor unit. When the frequence of outdoor unit  
change to 62Hz(6kw and 8kw)  or  44Hz (10kw  and 12kw)  
then running it; indoor fan run in high speed. Press the button again 
will exit the Force Cooling Control.    

10kw  and  12kw 

6kw  and  8kw 

 

sw2 sw1 

PMV opening

Actual current value

Actual voltage AD value

T2/T2B average temperature

Total quantities of the interior 
units

The last fault or protection 
code (if there is no fault or 
protection code it will be 
display “00”)

Display “--”

Normal display

Operating mode 
(0—Standby; 2—Cooling; 
3—Heating; 4—Forced 
cooling

Operating fan speed grade 
(0—Power off;1—Low fan 
speed;

The total capacity 
requirements of the 
interior unit

T3 piping temperature 

T4 environmert temperature

Tp discharge temperature 
(actual) (if it is over one 
hundred, it will be only 
display the hundreds
 place and the tens place)

2—High fan speed) 

Actual voltage AD value

Actual voltage AD value

(Fish checking)

 

The surface temperature of 
the cooling fin

PMV opening

Actual current value

Actual voltage AD value

T2 average temperature

Total quantities of the interior 
units

The quantities of the operating 
interior units

The last fault or protection 
code (if there is no fault or 
protection code it will be 
display “00”)

Display “--”

Normal display

Operating mode 
(0—Stanby; 2—Cooling; 
3—Heating; 4—Forced 
cooling

Operating fan speed grade 
(0—Power off)

The total capacity 
requirements of the 
interior unit

The capacity requirements
 of the revised external unit

T3 piping temperature 

T4 environmert temperature

T5 discharge temperature 
(actual) (if it is over one 
hundred, it will be only 
display the hundreds
 place and the tens place)

Summary of Contents for LRSJF-V N1

Page 1: ...OWNER S MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference DC INVERTER FREE...

Page 2: ...ide air inlet air outlet Fig 1 All the pictures in this manual are for explanation purpose only They may be slightly different from the heat pump you purchased depend on model The actual shape shall p...

Page 3: ...gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the heat pump until a service person confirms that the portion where the...

Page 4: ...in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components shorten their service life spans because of overheated for a long time The...

Page 5: ...el of indoor unit flashes And then unit will auto restart Mishandling in operation If mishandling happens because of lighting or mobile wireless please shut off the manual power switch and turn on aga...

Page 6: ...1 Model E0 E2 E3 E4 E5 P0 P1 P2 P3 P4 P5 P6 P8 P7 EEPROM error Communication error of the outdoor chip and the indoor chip Communication error of 9177and IPDU Communication error of outdoor chip and...

Page 7: ...above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures see in Table 7 1 7 1 Troubles and causes of heat pump 5 owner s manua...