background image

Installation of the Water Heater

Prior to the installation of the water heater, please contact 

the local gas company or the gas management department 

to select qualified gas pipe, pressure regulating valve, steel 

cylinder, clamp, smoke exhaust pipe and so on. You must 

entrust a qualified and specialized technician to install the 

gas  water  heater.  (Note:  The  user  cannot  install  the  gas 

water heater himself/herself, since an improper installation 

can bring a great impact on the safety performance, or even 

threaten  the  user’s  life.)  Prior  to  the  installation,  please 

reconfirm whether the type of gas you are using agrees with 

the  type  of  gas  specified  on  the  rating  plate  of  the  water 

heater.
This water heater is a flue gas water heater, which can be 

used only after all exhaust gases vented to the outdoors in 

strict  accordance  with  the  requirements.  It  is  forbidden  to 

use this water heater if the smoke exhaust pipe fails to be 

correctly  installed  according  to  the  requirements  in  this 

manual.
Since  each  user  has  his/her  own  building  structure,  this 

company cannot provide a uniform smoke exhaust pipe. The 

user can purchase his/her proper smoke exhaust pipe based 

on his/her own building structure.

Installation Requirements

1.  Do not install the water heater in bathrooms;
2.  Do not install the water heater in a place where there is 

strong wind, otherwise the flame of the water heater will 

be blown out or an incomplete combustion will occur.

3.  Do not install the water heater in the outdoors.
4.  Do not install the water heater in a confined room. Install 

it in a well-ventilated room with a volume more than 

7.5 m³. There should be an air inlet with an area more 

than 0.06

connected to the outdoors. A smoke exhaust 

pipe must be also installed.

5.  Install the water heater in a place where the line of sight 

and  the  viewport  are  at  the  same  level,  that  is, 

1.55~1.65m  above  the  ground,  and  where  the  water 

heater is distant from combustibles.

6.  Do not place any electric open wire, electric appliance or 

gas  pipeline  above  the  installation  site  of  the  water 

heater.  Keep  a  horizontal  distance  more  than  40cm 

between  the  water  heater  and  electric  appliances.  Do 

not install any gas appliance such as the gas oven and 

the gas range underneath the water heater.

7. Keep a distance greater than 150mm between the water 

heater and the surrounding walls and the ceiling. Build 

the  installation  site  with  noncombustible  materials. 

Otherwise,  insulate  the  water  heater  with  a  heat 

insulating  panel.  The  distance  between  the  insulating 

panel and the surrounding walls should be greater than 

10mm.

8.  Install an inlet valve in the water inlet pipe of the water 

heater.

9.  Place the vent of the smoke exhaust pipe in the outdoors.

10. For liquefied petroleum gas users, select qualified gas 

pressure  regulating  valves  and  hoses  to  ensure  the 

water  heater  a  proper  operation  and  security  use;  for 

pipeline gas users, ask the gas company or the relevant 

management authority to connect gas pipes.

After the flue gas water heater is installed with a smoke 

exhaust  pipe,  during  the  use,  do  not  turn  on  any 

mechanical  ventilation  equipment  such  as  the  smoke 

exhaust ventilator and the exhaust fan in the room where 

the water heater is installed or to which the water heater is 

connected. 

Note:  The connectors at the bottom would be in a 

different order for different models. Make the real 

object as the standard during the connection.

Shower 

Nozzle

Smoke 

Exhaust Pipe
Water Heater

Outlet Pipe
Water Inlet 

Air Intake

Air Intake

Outlet Valve 

Outlet 

Valve 

Inlet Valve 

Gas Intake Pipe

Water Source

150mm 

above 

150mm 

above 

150mm 

above 

Summary of Contents for JSQ Series

Page 1: ...er The diagram above is just for reference Please take the appearance of the actual product as the standard Please read the instruction manual carefully before installing and operating this water heat...

Page 2: ...8 Water gas Linkage Control The water heater will automatically stop combustion and shut down when the supply of tap water is suspended or the water valve is shut off 9 Over pressure Protection When...

Page 3: ...le Water Pressure Rated Yield Capacity of the Hot Water Temperature Rise 25k Gas Inlet Cold Water Inlet Hot Water Inlet Dimensions L W H Net Weight Diameter of the Smoke Vent JSQ Series Liquefied Petr...

Page 4: ...A smoke exhaust pipe must be also installed 5 Install the water heater in a place where the line of sight and the viewport are at the same level that is 1 55 1 65m above the ground and where the water...

Page 5: ...be greater than 20mm when the flue pipe passes through the wall made up of combustible materials f Try not to hide the flue pipe inside the ceiling Wrap up the flue pipe with heat insulating materials...

Page 6: ...let water temperature can be increased switch the firepower regulation knob to Min or switch the water temperature regulation knob to Low the outlet water temperature can be decreased 3 When the firep...

Page 7: ...t ignite the water heater or switch on any electrical appliance Open all doors and windows to automatically vent the gas to the outdoors Stop using the water heater and contact the maintenance departm...

Page 8: ...by the water heater is not potable just used as non potable water 2 Freezing prevention When the water heater is used in cold areas where the ambient temperature is below 0 C the water stored in the...

Page 9: ...o yellow and there arises black smoke contact the technician in time for cleaning 3 Frequently use soft cleaning cloth to wipe the hull of the water heater with clean water or neutral detergent rather...

Page 10: ...der the following circumstances The water heater cannot ignite No hot water flows out The water is not hot enough The water is too high The main gas valve is not opened There is air in the gas pipe Th...

Page 11: ...ance of the technician in our special service department c No valid proof of purchase d Valid proof of purchase altered e The model number and product code registered in the installation card in disag...

Page 12: ...lation personnel take the gas leak test with the soapy water Do the installation personnel inform you to take the gas leak test Do the installation personnel demonstrate to you how to change batteries...

Page 13: ...l take the gas leak test with the soapy water Do the installation personnel inform you to take the gas leak test Do the installation personnel demonstrate to you how to change batteries Do the install...

Reviews: