![Midea HS-36I Service Manual Download Page 8](http://html1.mh-extra.com/html/midea/hs-36i/hs-36i_service-manual_1791252008.webp)
Maintenance Service and Trouble Shooting
2 The compressor doesn't stop
Compressor doesn't
stop
Does the appliance
refrgerate?
NO
Check and repair according to
the section of "No cooling".
YES
Is cooling capacity
insufficient.
NO
Check and repair according to
the section of "Cooling capacity
is insuffcient".
YES
1 The thermostat was
set at the coldest position.
2 The ambient temperature is very high or
the appliance is near by heat resource.
3 The door was opened too many
times or there are more
fresh food inside.
NO
Adjust and instruct
consumer how to use.
NO
Check and repair the main
control panel
11