Service Manual_2018-V2.0
29
9. Function and operation
9.1 Operation panel
❶
Standby button
❷
Lighting button
❸
Display area
❹
Temperature increase button
❺
Temperature decrease button
❻
℉
/
℃
button
9.2 Display control
If power on for 1st time, the display area will shine fully last for 3 seconds with the start-up tone, then enter
in normal running state, the default set temperature is 12
℃
,
14
℃
.
Normal operation display:
1
)
When failure occurs, will display the fault code (circular display);
2
)
The set temperature in the case of no failure.
9.3 Temperature control
1)click the key of temperature up once, the setting temperature rise 1
℃
(
℉
), click the key of
temperature down once, the setting temperature drop 1
℃
(
℉
), the temperature setting take effect
automatically after 30s
2) in Centigrade showing, the adjustable temperature range is 1 to 10; in Fahrenheit showing, the
adjustable temperature range is from 41 to 64, short press the key of Centigrade
– Fahrenheit conversion
to realize the conversion between Centigrade and Fahrenheit
9.4 Control of standby function
Press standby button for 5 seconds to enter/exit standby mode;
When the standby mode is in effect, the compressor, refrigerator room fan, condenser fan, and
lighting do not work;
Note: The standby mode cannot be set when the sensor is faulty, and the door is not alarmed when
in standby mode.
9.5 Open door alarm (None)
9.6 Defrosting function
Manual defrost