CONTROL PADS ON THE DEHUMIDIFIER

Control pads

3

3

When you push the button to change
operation modes, the unit will make 
a beep sound to indicate that it is 
changing modes.

NOTE:

 The control panel of the unit you purchased may be slightly different according to the 

models. 

Fig.1

2

2

Humidity Set Control Pads

: Down/Up Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto start and 
Auto stop time from 0.0 to 24.

The humidity level can be set within a range of 
35%RH(Relative Humidity) to 85%RH(Relative 
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower 
percent value(%). 
For damper air, press the      pad and set  a higher 
percent value(%).

CONTROL PADS ON THE DEHUMIDIFIER

Other features 

Bucket Full Light

Glows when the bucket  is ready to be 
emptied, or when the bucket is removed
or not replaced in the proper position.

When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue 
to run until the frost disappears.
NOTE:When Auto defrosting operation,the unit may 
make a voice of refrigerant flowing,it is normal.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart 
opertation in the first 3 minutes. This is to protect 
the unit. Operation will automatically start after 
3 minutes.

Setting the Timer

 When the unit is on, first  press the Timer 
 button,  the Timer Off indicator light 
 illuminates. It indicates the Auto Stop 
 program is initiated. Press it again the 
 Time On indecator light illuminates.It 
 indicates the Auto Start is initiated.
 

 Press or hold the UP or DOWN pad to 
 change the Auto time by 0.5 hour incre-
 ments,  up to 10 hours, then at 1 hour 
 increments up to 24 hours. The control  
 will count down the time remaining until 
 start. 
 The selected time will register in 5 seconds 
 and the system will automatically revert 
 back to display the previous humidity 
 setting.
 When the Auto start & Auto stop times are
 set, within the same program sequence, 
 TIMER ON OFF indicator lights illuminate 
  identifying both ON and OFF times are
  now programmed.
 Turning the unit ON or OFF at any time or 
 adjusting the timer setting to 0.0 will cancel
 the Auto Start/Stop function.
 When LED display window displays the
 code of  P2, the Auto Start/Stop function 
 will also be cancelled.

When the unit is off, first  press the Timer 

 button, the TIMER ON indicator light 
 illuminates. It indicates the Auto Start 
 program is initiated. Press it again the 
 Time Off indecator light illuminates.It 
 indicates the Auto Stop is initiated.

Display

Shows the set % humidity level from 35% to 85% or auto 
start/stop time (0~24) while setting, then shows the actual
(

5% accuracy) room % humidity level in a range of 30%

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Codes:
AS

- Humidity sensor error--Unplug the unit and plug it back

in. If error repeats, call for service.

ES

- Temperature sensor error-- Unplug the unit and plug it 

back in. If error repeats, call for service.

5

5

Timer Pad

Press to initiate the Auto start and Auto stop feature, 
in conjuction with the       and         key pads.

Auto Shut Off

The dehumidifier shuts off when the bucket  is full, 
or when the bucket is removed or not replaced in 
the proper position.When the setting humidity is 
reached, the unit will be shut off automatically. 
For some models,the fan motor will continue 
operating.

Auto-Restart

If the unit breaks off unexpectedly due to the power cut, 
it will restart with the previous function setting automa-
tically when the power resumes.

1

1

4

4

Power Pad

Press to turn the dehumidifier on and off.

1

1

2

2

3

3

4

4

5

5

6

6

7

7

Unit operation on
indicator light

8

8

High fan 
indicator light

Timer on/off
indicator light

Ion operation on
indicator light

Bucket full 
indicator light

Continuous
operation on
indicator light

Dryer operation 
on indicator light

Smart dehumidifying
operation on indicator 
light

Mode Pad

Press to select the desired operation mode from
Dehumidifying,Dryer,Continuous dehumidifying and
Smart dehumidifying. 
NOTE: Dryer and Smart dehumidifying modes are
optional.

 

6

6

Turbo Pad

7

7

Ion Pad(optional)

Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.

Control the fan speed. Press to select either High 
or Normal fan speed. Set the fan control to High for  
maximum moisture removal. When the humidity has 
been reduced and quiet operation is preferred, set 
the fan control to Normal.

8

8

P1

- Unit is defrosting-- Allow the unit time to automatically

defrost. The protection will clear after the unit self defrosts.

P2

- Bucket is full or bucket is not in right position-- Empty 

the bucket and replace it in the right position.

E3

- Unit malfunction-- Unplug the unit and plug it back in. If 

error repeats, call for service.

EC

-Refrigerant leakage detection-- With this new technology,

the display area will appear   EC   when the unit detects 
refrigerant leakage ,call for service.

Smart dehumidifying mode(optional)

At smart dehumidifying mode, the unit will automatically 
control room humidity in a comfortable range 45%~55% 
according to the room temperature. The humidity setting 
function will be invalid.

NOTE: When the compressor startups or stops
running,the unit may make a loud voice,it is normal.

Summary of Contents for Comfee MDDF-16DEN3

Page 1: ...bject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details The design and specifications are subject to change without prior notice for prod...

Page 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troublesho...

Page 3: ...the unit and cause electric shock Do not take the water buc ket out during operation SAFETY PRECAUTIONS Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to...

Page 4: ...humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Code...

Page 5: ...r more Positioning the unit Do not use outdoors This dehumidifer is intended for indoor residential applications only This dehumidifier should not be used for commercial or industrial applications Pla...

Page 6: ...water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock cause the insulation to deteriorate or cause the unit...

Page 7: ...idity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something givin...

Reviews: