Service manual
44
Yes
13.1.5
Display LED
STATUS
E5
Open or short circuit of outdoor temperature sensor
Yes No
13.1.6
Display LED
STATUS
E6
Room temperature or evaporator temperature sensor open or short circuit
yes
No
13.1.7
Display LED
STATUS
P0 Module
protection
Is connector connection good?
Is voltage being applied to the fan motor?
(rang 90v-160v between mid pin and N on CN1
Indoor fan motor is defective
Repair the connector.
Indoor PCB is defective
No
Yes
No
Is connection to connector good?
Replace the sensor
Repair connector
Is connection to connector good?
Replace the sensor
Repair connector
If display E5 all the same, replace indoor main PCB.
If display E6 all the same, replace outdoor main PCB.
Replace indoor main PCB.
Replace indoor fan motor.
Summary of Contents for AAC-18ISCH
Page 4: ......
Page 16: ...Service manual 12 5 Refrigerant cycle diagram...
Page 20: ...Service manual 16 7 1 5 Indoor main PCB Inverter Eco...
Page 21: ...Service manual 17 7 1 6 Outdoor main PCB Inverter Eco...
Page 22: ...Service manual 18 7 2 Wiring diagram 7 2 1 MSH 18HRDN1...
Page 23: ...Service manual 19 7 2 2 MSC 18HRIN1...
Page 24: ...Service manual 20 7 2 3 MSE 09HRIN2 MSE 12HRIN2...